Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Somatic TP53 Mutations in Formalin-Fixed, Paraffin-Embedded (FFPE) Tissue

Somatic TP53 Mutations in Formalin-Fixed, Paraffin-Embedded (FFPE) Tissue: ARUP Laboratories test 3017688

ARUP Laboratories test 3017688, CPT 81351. Specimen: Tumor tissue.. Turnaround: 12-14 days.

Somatic TP53 Mutations in Formalin-Fixed, Paraffin-Embedded (FFPE) Tissue is ARUP Laboratories test code 3017688, billed with CPT 81351. Specimen: Tumor tissue.. Turnaround time: 12-14 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3017688
CPT81351
LOINC103680-5, 57723-9
SpecimenTumor tissue. New York State Clients: Paraffin-embedded tissue.
Turnaround time12-14 days
Storage / transportRoom temperature. Also acceptable: Refrigerated. Ship in cooled container during summer months. New York State Clients: Refrigerated. Also acceptable: Room temperature.

Use

Use to identify TP53 mutations in formalin-fixed, paraffin-embedded (FFPE) tissue from various tumors. TP53 mutation status is a prognostic biomarker in many tumor types, including lymphoid malignancies.

Methodology

Qualitative Massively Parallel Sequencing

Collection instructions

Formalin-fixed (10 percent neutral buffered formalin) and paraffin-embedded tissue. Diff-Quik- and Papanicolaou-stained cytology smears are also acceptable. Number of slides needed for testing is dependent on the tumor cellularity of the smear. Slide(s) will be destroyed during testing process and will not be returned to client. Protect from excessive heat. Transport block and/or slides in a tissue transport kit (ARUP supply # 47808 ) available online through eSupply using ARUP Connect(TM) or contact ARUP Client Services at 800-522-2787. Resections: Transport 8 unstained 5-micron slides. (Min: 5 slides) Small Biopsies: Transport 15 unstained 5-micron slides. (Min: 10 slides) New York State Clients: Submit 7-10 unstained slides cut at 10 microns thick.

Stability

Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Unacceptable

Causes for rejection

Less than 10 percent tumor. Specimens fixed in any fixative other than 10 percent neutral buffered formalin. Decalcified specimens processed in a non-EDTA decalcifier. FNA smears with less than 50 tumor cells.

Remarks

Include surgical pathology report. If multiple specimens (blocks or slides) are sent to ARUP, they must be accompanied by one of the following: an order comment indicating that the ARUP pathologist should choose the specimen most appropriate for testing (e.g., "Choose best block") or individual orders for each sample submitted. A Pathologist Block Selection Fee (ARUP test code 3002076) will be added to orders that utilize the first option. If multiple specimens are sent to ARUP without a request for pathologist block/slide selection or individual orders, they will be held until clarification is provided.

Performed

Varies

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

Testing is not New York state approved. Specimens from New York clients will be sent out to a New York state-approved laboratory.

LOINC map

Result codeResult nameUnitsResult LOINC
2002148Block ID57723-9
3017689TP53 FFPE Interp103680-5

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 81351

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation