Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Connexin 26 ( GJB2 ) Sequencing and Deletion/Duplication

Connexin 26 ( GJB2 ) Sequencing and Deletion/Duplication: ARUP Laboratories test 3004720

ARUP Laboratories test 3004720, CPT 81252, 81479. Specimen: Lavender or pink (EDTA) or yellow (ACD solution A or B).. Turnaround: 10-15 days.

Connexin 26 ( GJB2 ) Sequencing and Deletion/Duplication is ARUP Laboratories test code 3004720, billed with CPT 81252, 81479. Specimen: Lavender or pink (EDTA) or yellow (ACD solution A or B).. Turnaround time: 10-15 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3004720
CPT81252; 81479
LOINC66746-9, 90851-7
SpecimenLavender or pink (EDTA) or yellow (ACD solution A or B). New York State Clients: Lavender (EDTA) or yellow (ACD solution)
Turnaround time10-15 days
Storage / transportRefrigerated.

Also known as: Deafness autosomal dominant 3A (DFNA3A); Deafness autosomal recessive 1A (DFNB1A); GJB2-related nonsyndromic hearing loss and deafness

Use

Diagnostic testing or carrier screening for GJB2 -related nonsyndromic hearing loss (NSHL). May be used as first-tier genetic test for individuals with severe-to-profound congenital NSHL.

Methodology

Massively Parallel Sequencing

Collection instructions

Transport 3 mL whole blood. (Min: 3 mL) New York State Clients: 7 mL (Min. 3 mL)

Stability

Ambient: 72 hours; Refrigerated: 1 week; Frozen: Unacceptable

Causes for rejection

Serum or plasma; grossly hemolyzed or frozen specimens; saliva, buccal brush, or swab; FFPE tissue.

Reference range

Refer to report

Performed

Varies

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

Testing is not New York state approved. Specimens from New York clients will be sent out to a New York state-approved laboratory.

LOINC map

Result codeResult nameUnitsResult LOINC
3004721CX26 Specimen66746-9
3004722CX26 Interp90851-7

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 81252, 81479

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation