Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Circulating Immune Complex Panel

Circulating Immune Complex Panel: ARUP Laboratories test 3004430

ARUP Laboratories test 3004430, CPT 86332. Specimen: Plain red or serum separator tube (SST).. Turnaround: 2-9 days.

Circulating Immune Complex Panel is ARUP Laboratories test code 3004430, billed with CPT 86332. Specimen: Plain red or serum separator tube (SST).. Turnaround time: 2-9 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3004430
CPT86332 x2
LOINC27831-7, 5228-2
SpecimenPlain red or serum separator tube (SST).
Turnaround time2-9 days
Storage / transportCRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.

Also known as: C1q binding Immune Complexes; C1q binding; CIC; C3 fragment containing immune complexes; CIC-Raji Cell Replacement assay; Circulating Immune Complex Panel

Use

Use to detect circulating immune complexes.

Methodology

Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)

Collection instructions

Allow complete clotting of red blood cells (up to 1 hour), then separate serum from cells within 30 minutes and freeze immediately. Transfer TWO (2) 1 mL aliquots of serum to individual ARUP Standard Transport Tubes. (Min: 0.5 mL/aliquot)

Stability

Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 2 weeks

Causes for rejection

Non-frozen specimens. Specimens exposed to repeated freeze/thaw cycles. Grossly hemolyzed, lipemic, and icteric specimens.

Reference range

Binding less than or equal to 3.9 ug Eq/mL is considered negative for circulating complement binding immune complexes. Test Number Components Reference Interval Circulating Immune Complex, C1q Binding Less than or equal to 3.9 µg Eq/mL Circulating Immune Complex, C3 fragments Less than or equal to 15 µg Eq/mL

Performed

Mon, Thu, Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050301Circulating Immune Complex, C1q Binding27831-7
3004432Circulating Immune Complex, C3 fragments5228-2

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86332

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation