Solid Tumor Mutation Panel, Sequencing: ARUP Laboratories test 3004294
ARUP Laboratories test 3004294, CPT 81445. Specimen: Tumor tissue.. Turnaround: 12-14 days.
Also known as: Solid Tumor Next Gen sequencing
Use
Use to assess for targeted variants that are useful for prognosis and/or treatment of individuals with solid tumor cancers, including melanoma, gastrointestinal stromal tumor (GIST), colorectal, bladder, and hepatocellular carcinomas, at initial diagnosis or in the presence of refractory disease. If the clinical indication is lung cancer, additional molecular genetic testing may be considered for detection of gene rearrangements and/or c-MET exon 14-skipping alterations. For evaluation of microsatellite instability, additional molecular testing should be considered.
Methodology
Massively Parallel Sequencing
Collection instructions
Formalin fix (10 percent neutral buffered formalin) and paraffin embed tissue. Diff-Quik- and Papanicolaou-stained cytology smears are also acceptable. Number of slides needed is dependent on the tumor cellularity of the smear. Slide(s) will be destroyed during testing process and will not be returned to client. Protect from excessive heat. Transport block and/or slides in a tissue transport kit (ARUP supply # 47808 ) available online through eSupply using ARUP Connect™ or contact ARUP Client Services at 800-522-2787. Resections: Transport 8 unstained 5-micron slides. (Min: 5 slides) Small Biopsies: Transport 15 unstained 5-micron slides. (Min: 10 slides)
Stability
Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Unacceptable
Causes for rejection
Less than 10 percent tumor. Specimens fixed in any fixative other than 10 percent neutral buffered formalin. Decalcified specimens. FNA smears with less than 50 tumor cells.
Remarks
Include surgical pathology report. If multiple specimens (blocks or slides) are sent to ARUP, they must be accompanied by one of the following: an order comment indicating that the ARUP pathologist should choose the specimen most appropriate for testing (e.g., "Choose best block"), or individual orders for each sample submitted. A Pathologist Block Selection Fee (ARUP test code 3002076) will be added to orders that utilize the first option. If multiple specimens are sent to ARUP without a request for pathologist block/slide selection or individual orders, they will be held until clarification is provided.
Performed
Varies
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is not New York state approved. The performing laboratory will submit an NYDOH Single Use Permit (SUP) upon receipt of order. If SUP is approved by NYDOH, testing will be performed.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2007992 | Solid Tumor Panel by NGS Block ID | 94736-6 | |
| 2007993 | Solid Tumor Panel By NGS Interpretation | ||
| 3003988 | EER Solid Tumor Panel NGS | 11502-2 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 81445
- Colorectal Cancer NGS Panel
- Head and Neck Next Generation Sequencing
- Lung Cancer Mutation Panel
- Lung Cancer NGS Panel
- Melanoma NGS Panel
- MLH1/MSH2/MSH6/PMS2/EPCAM Somatic Tumor Mismatch Repair Sequencing and Deletion/Duplication Test
- Solid Tumor NGS Panel
- MLH1/MSH2/MSH6/PMS2/EPCAM Somatic Tumor Mismatch Repair Sequencing and Deletion/Duplication Test
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation