Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › AAV8 Total Antibody Assay

AAV8 Total Antibody Assay: ARUP Laboratories test 3003895

ARUP Laboratories test 3003895. Specimen: Serum separator tube. Turnaround: 7-10 days.

AAV8 Total Antibody Assay is ARUP Laboratories test code 3003895. Specimen: Serum separator tube. Turnaround time: 7-10 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3003895
CPT—
LOINC—
SpecimenSerum separator tube
Turnaround time7-10 days
Storage / transportCritical frozen

Use

The AAV8 Total Antibody Assay is a laboratory-developed test intended for the qualitative detection of antibodies in human blood serum specimens that bind to adeno-associated virus serotype 8 (AAV8).

Methodology

Qualitative Electrochemiluminescent Immunoassay (ECLIA)

Collection instructions

Transfer 1 mL serum to an ARUP standard transport tube. (Min: 0.5 mL)

Stability

Frozen (-10 C or colder): Acceptable; Ambient: Unacceptable; Refrigerated: Unacceptable

Causes for rejection

Hemolyzed specimens. Anything other than published.

Remarks

Collect the patient’s whole blood in a serum separator tube. NOTE: When drawing blood for the AAV8 Total Antibody Assay, universal precautions for bloodborne pathogens should be observed. Centrifuge the specimen and separate the serum within 72 hours of collection. Refer to your manufacturer’s manual for recommended centrifuge speed and duration. Transfer 1 mL (minimum: 0.5 mL) of serum into a polypropylene pour-off (transport) tube. Sample stability for the AAV8 Total Antibody Assay has not been evaluated in tube types other than the ARUP transport tube (polypropylene). Failure to provide sufficient volume may result in the need for patient redraw. Label the transport tube with the patient’s first and last name, date of birth, and sex. Freeze serum specimen at -10 C or below. Ship frozen serum specimens to ARUP as soon as possible and use overnight delivery to ensure next day arrival at ARUP. NOTE: Serum specimens must be frozen before they are shipped to ARUP Laboratories. NOTE: HCPs in New York who would like to order this test should contact ARUP Client Services for more information.

Performed

Mon-Fri

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is not New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3003896AAV8 Total Antibody Assay Result

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation