Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Hepatitis Panel, Acute with Reflex to HBsAg Confirmation and Reflex to HCV by Quantitative NAAT

Hepatitis Panel, Acute with Reflex to HBsAg Confirmation and Reflex to HCV by Quantitative NAAT: ARUP Laboratories test 3002989

ARUP Laboratories test 3002989, CPT 80074, 87341, 87522. Specimen: Serum separator tube (SST), lavender (EDTA), or pink (K2EDTA).. Turnaround: 1-2 days.

Hepatitis Panel, Acute with Reflex to HBsAg Confirmation and Reflex to HCV by Quantitative NAAT is ARUP Laboratories test code 3002989, billed with CPT 80074, 87341, 87522. Specimen: Serum separator tube (SST), lavender (EDTA), or pink (K2EDTA).. Turnaround time: 1-2 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3002989
CPT80074; if reflexed, add 87341; 87522
LOINC13950-1, 13955-0, 24113-3, 48767-8, 5196-1, 57006-9
SpecimenSerum separator tube (SST), lavender (EDTA), or pink (K2EDTA).
Turnaround time1-2 days If reflexed, add 1-3 days.
Storage / transportFrozen.

Also known as: Acute Hep Panel, reflex to confirmation; HAV IgM Ab; HBsAg confirmation; HBV core IgM Ab; HCV Ab; Hep Panel reflex to confirmation; Hepatitis A Antibody, IgM; Hepatitis B Core Antibody, IgM; Hepatitis B Surface Antigen; Hepatitis C Antibody; Hepatitis C Antibody by CIA; Hepatitis panel; Hepatitis screening panel; Hepatitis Screening Profile, Serum; Hepatitis, Acute Panel; Viral hepatitis panel

Use

Preferred panel to evaluate symptomatic patients for viral hepatitis. If acute HCV infection is suspected, the recommended test is Hepatitis C Virus (HCV) by Quantitative NAAT ( 3000572 ). This panel includes HAV IgM, HBV core antibody IgM, HBV surface antigen, and HCV antibody with reflex to HCV by quantitative NAAT.

Methodology

Qualitative Chemiluminescent Immunoassay (CLIA) / Quantitative Polymerase Chain Reaction (PCR)

Collection instructions

Separate serum from cells ASAP or within 2 hours of collection. Transfer 3.0 mL serum or plasma to an ARUP standard transport tube (Min: 2.5 mL). This test requires a dedicated transport tube submitted only for HEPACUTEQR testing.

Stability

After separation from cells: Ambient: 24 hours; Refrigerated: 6 days; Frozen: 30 days (avoid repeated freeze/thaw cycles)

Causes for rejection

Heparinized plasma. Specimens containing particulate material. Heat-inactivated, severely hemolyzed, or lipemic specimens.

Reference range

Test Number Components Reference Interval Hepatitis B Surface Antigen Negative Hepatitis C Antibody by CIA Interp Negative Hepatitis B Core Antibody, IgM Negative Hepatitis A Antibody, IgM Negative

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0020089Hepatitis B Surface Antigen5196-1
0020092Hepatitis B Core Antibody, IgM24113-3
0020093Hepatitis A Antibody, IgM13950-1
2002404Hepatitis C Antibody by CIA Index57006-9
3003010Hepatitis, Acute Panel w/ Rflx Interp48767-8
3003128Hepatitis C Antibody by CIA Interp13955-0

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 80074, 87341, 87522

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation