Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › TFE3 Gene Rearrangement by FISH

TFE3 Gene Rearrangement by FISH: ARUP Laboratories test 3002633

ARUP Laboratories test 3002633, CPT 88366. Specimen: Tumor tissue.. Turnaround: 3-7 days.

TFE3 Gene Rearrangement by FISH is ARUP Laboratories test code 3002633, billed with CPT 88366. Specimen: Tumor tissue.. Turnaround time: 3-7 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3002633
CPT88366
LOINC31208-2, 35474-6, 78236-7, 80398-1, 81304-8
SpecimenTumor tissue.
Turnaround time3-7 days
Storage / transportRoom temperature. Also acceptable: Refrigerated. Ship in cooled container during summer months.

Use

Aids in the diagnosis of renal cell carcinoma (RCC) and alveolar soft part sarcoma (ASPS).

Methodology

Fluorescence in situ Hybridization (FISH)

Collection instructions

Formalin fix (10 percent neutral buffered formalin) and paraffin embed specimen. Protect paraffin block from excessive heat. Transport tissue block or 5 unstained (4- micron thick sections), positively charged slides in a tissue transport kit (ARUP supply # 47808 ), available online through eSupply using ARUP Connect(TM) or contact ARUP Client Services at (800) 522-2787 (kit recommended but not necessary). (Min: 2 slides)

Stability

Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Unacceptable

Causes for rejection

Paraffin block with no tumor tissue remaining. Specimens fixed in any fixative other than 10 percent neutral buffered formalin. Decalcified specimens.

Remarks

Include surgical pathology report. If multiple specimens (blocks or slides) are sent to ARUP, they must be accompanied by one of the following: an order comment indicating that the ARUP pathologist should choose the specimen most appropriate for testing (e.g., "Choose best block"), or individual orders for each sample submitted. A Pathologist Block Selection Fee (ARUP test code 3002076) will be added to orders that utilize the first option. If multiple specimens are sent to ARUP without a request for pathologist block/slide selection or individual orders, they will be held until clarification is provided.

Performed

Mon-Fri

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3000703Scoring Method81304-8
3002634TFE3 Ref Number80398-1
3002635TFE3 Source31208-2
3002636TFE3 Result35474-6
3002953Total Cell Count78236-7

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 88366

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.