Meningitis/Encephalitis Panel by PCR: ARUP Laboratories test 2013305
ARUP Laboratories test 2013305, CPT 87483. Specimen: CSF. Turnaround: Within 24 hours.
Also known as: Film Array Panel
Use
Use to rapidly detect a panel of common viruses, bacteria, and fungi associated with meningitis and encephalitis. Do NOT use as a replacement for CSF bacterial and/or fungal culture and Cryptococcal antigen testing for at-risk patients. A negative result does not exclude a diagnosis of meningitis or encephalitis due to infection.
Methodology
Qualitative Polymerase Chain Reaction (PCR)
Collection instructions
Transfer 0.5 mL CSF to a sterile ARUP standard transport tube (ARUP supply # 43115 ) available online through eSupply using ARUP Connect(TM) or contact ARUP Client Services at 800-522-2787. (Min: 0.25 mL) Do not centrifuge.
Stability
Ambient: 24 hours; Refrigerated: 1 week; Frozen: 1 week
Patient preparation
N/A
Causes for rejection
N/A
Remarks
N/A
Performed
Sun-Sat
Compliance Category
FDA
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2013306 | Cytomegalovirus by PCR | 82189-2 | |
| 2013307 | Cryptococcus neoformans/gattii by PCR | 82181-9 | |
| 2013308 | Escherichia coli K1 by PCR | 82182-7 | |
| 2013309 | Enterovirus by PCR | 82194-2 | |
| 2013310 | Haemophilus influenzae by PCR | 82183-5 | |
| 2013311 | Human herpesvirus 6 by PCR | 82192-6 | |
| 2013312 | Herpes simplex virus 1 by PCR | 82190-0 | |
| 2013313 | Herpes simplex virus 2 by PCR | 82191-8 | |
| 2013314 | Listeria monocytogenes by PCR | 82184-3 | |
| 2013315 | Neisseria meningitidis by PCR | 82185-0 | |
| 2013316 | Human parechovirus by PCR | 82193-4 | |
| 2013317 | Streptococcus agalactiae by PCR | 82186-8 | |
| 2013318 | Varicella zoster virus by PCR | 82188-4 | |
| 2013319 | Streptococcus pneumoniae by PCR | 82187-6 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 87483
- Meningitis Encephalitis Panel by PCR
- Meningitis/Encephalitis panel
- Meningitis/Encephalitis Pathogen Panel, NAA, Cerebrospinal Fluid (CSF)
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation