SLCO1B1 , 1 Variant: ARUP Laboratories test 2008426
ARUP Laboratories test 2008426, CPT 81328. Specimen: Lavender (EDTA) or pink (K2EDTA), or yellow (ACD Solution A or B).. Turnaround: 5-10 days.
Also known as: Simvastatin myotoxicity assay; Statin-induced myopathy assay
Use
Identify individuals at increased risk for statin-related muscle toxicity.
Methodology
Polymerase Chain Reaction (PCR) / Fluorescence Monitoring
Collection instructions
Transport 3 mL whole blood. (Min: 1 mL)
Stability
Room temperature: 3 days; Refrigerated: 1 week; Frozen: 1 month
Causes for rejection
Plasma or serum. Heparinized specimens. Frozen specimens in glass collection tubes.
Reference range
Refer to report
Remarks
Counseling and informed consent are recommended for genetic testing. Consent forms are linked above. New York Clients: informed consent is required with submission.
Performed
Mon, Thu
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2008427 | SLCO1B1, 1 Variant, Specimen | 66746-9 | |
| 2008428 | SLCO1B1, 1 Variant,*5 Genotype | 93412-5 | |
| 3016893 | EER SLCO1B1 | 11526-1 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.