Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Alternative Complement Pathway Activity (AH50)

Alternative Complement Pathway Activity (AH50): ARUP Laboratories test 2005373

ARUP Laboratories test 2005373, CPT 86161. Specimen: Plain Red. Turnaround: 7-14 days.

Alternative Complement Pathway Activity (AH50) is ARUP Laboratories test code 2005373, billed with CPT 86161. Specimen: Plain Red. Turnaround time: 7-14 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2005373
CPT86161
LOINC74520-8
SpecimenPlain Red
Turnaround time7-14 days
Storage / transportCRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.

Also known as: AH50; Hemolytic Complement; Alternate Pathway; atypical hemolytic uremic syndrome; C3 glomerulonephrits; Dense-deposit disease; Functional Complement

Use

Initial screening for suspected deficiency in the alternative complement pathway.

Methodology

Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)

Collection instructions

Allow specimen to clot for one hour at room temperature. Separate serum from cells ASAP and centrifuge at 2-8 degrees C and aliquot serum into ARUP standard transport tube. Freeze specimen immediately at -70 degrees C or lower freezer. (Min: 0.3 mL)

Stability

After separation from cells: Ambient: unacceptable; Refrigerated: Unacceptable; Frozen: 30 days if kept at -70 C

Causes for rejection

Specimen types other than serum collected from RED TOP tubes. SST or serum gel tubes are not acceptable. Refrigerated or room temperature specimens. Specimens left to clot at refrigerated temperature. Specimens exposed to repeated freeze/thaw cycles. Grossly hemolyzed or grossly lipemic specimens or icteric specimens.

Reference range

Test Number Components Reference Interval Alternative Complement Pathway Activity 31 percent normal or greater

Performed

Sun, Wed

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2005374Alternative Complement Pathway Activity74520-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86161

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation