Alternative Complement Pathway Activity (AH50): ARUP Laboratories test 2005373
ARUP Laboratories test 2005373, CPT 86161. Specimen: Plain Red. Turnaround: 7-14 days.
Also known as: AH50; Hemolytic Complement; Alternate Pathway; atypical hemolytic uremic syndrome; C3 glomerulonephrits; Dense-deposit disease; Functional Complement
Use
Initial screening for suspected deficiency in the alternative complement pathway.
Methodology
Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)
Collection instructions
Allow specimen to clot for one hour at room temperature. Separate serum from cells ASAP and centrifuge at 2-8 degrees C and aliquot serum into ARUP standard transport tube. Freeze specimen immediately at -70 degrees C or lower freezer. (Min: 0.3 mL)
Stability
After separation from cells: Ambient: unacceptable; Refrigerated: Unacceptable; Frozen: 30 days if kept at -70 C
Causes for rejection
Specimen types other than serum collected from RED TOP tubes. SST or serum gel tubes are not acceptable. Refrigerated or room temperature specimens. Specimens left to clot at refrigerated temperature. Specimens exposed to repeated freeze/thaw cycles. Grossly hemolyzed or grossly lipemic specimens or icteric specimens.
Reference range
Test Number Components Reference Interval Alternative Complement Pathway Activity 31 percent normal or greater
Performed
Sun, Wed
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 2005374 | Alternative Complement Pathway Activity | 74520-8 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 86161
- Alternative Complement Pathway Activity (AH50)
- C-1-Esterase Inhibitor Panel
- C1 Esterase Inhibitor Functional
- C1-Esterase Inhibitor Functional
- C2 Complement, Functional with Reflex, Serum
- C5 Complement, Functional
- C5 Inhibitors Drug Monitoring Panel
- Complement C 1
- Complement C1 Esterase Inhibitor, Functional
- Complement C5, Functional
- Complement C6, Functional
- Complement C7 Functional
- Complement C9 Functional
- Complement Component C8
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation