Ganglioside (GM1, GD1b, and GQ1b) Antibodies, IgG and IgM: ARUP Laboratories test 2004998
ARUP Laboratories test 2004998, CPT 83516. Specimen: Serum separator tube.. Turnaround: 1-8 days.
Also known as: GM1, GD1b, GQ1b IgG and IgM; Ganglioside Abs IgG and IgM; Anti-GM Antibodies; Ganglioside Antibodies; Ganglioside (GM1) Antibodies, IgG and IgM; GD1b IgG IgM; GQ1b IgG IgM
Use
May have diagnostic relevance in multifocal motor neuropathy (MMN), Guillain-Barré syndrome (GBS), and Miller Fisher syndrome (MFS). For a more comprehensive ganglioside antibody panel when evaluating patients with autoimmune neuropathies, refer to Ganglioside (Asialo-GM1, GM1, GM2, GD1a, GD1b, and GQ1b) Antibodies ( 0051033 ). Test by itself is not diagnostic and should be used in conjunction with other clinical parameters to confirm disease.
Methodology
Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)
Collection instructions
Transfer 0.3 mL serum to an ARUP Standard Transport Tube. (Min: 0.1 mL)
Stability
After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year.
Causes for rejection
CSF, plasma, or other body fluids. Room temperature specimens. Contaminated, heat-inactivated, hemolyzed, severely icteric, or lipemic specimens.
Reference range
Test Number Components Reference Interval GM1 Antibody, IgG 0-50 IV GM1 Antibody, IgM 0-50 IV GD1b Antibody, IgG 0-50 IV GD1b Antibody, IgM 0-50 IV GQ1b Antibody, IgG 0-50 IV GQ1b Antibody, IgM 0-50 IV
Performed
Thu
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 0050582 | GM1 Antibody, IgG | 51729-2 | |
| 0050584 | GM1 Antibody, IgM | 51703-7 | |
| 2004999 | GD1b Antibody, IgG | 56541-6 | |
| 2005000 | GD1b Antibody, IgM | 58977-0 | |
| 2005001 | GQ1b Antibody, IgG | 57660-3 | |
| 2005002 | GQ1b Antibody, IgM | 56545-7 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 83516
- 21-Hydroxylase Antibody
- 21-Hydroxylase Autoantibodies, Serum
- Acetylcholine Receptor and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
- Acetylcholine Receptor Antibodies and Striated Muscle Antibodies Reflexive Panels, and Titin Antibody
- Adrenal 21-Hydroxylase Autoantibodies (Endocrine Sciences)
- aHUS (complement-mediated TMA) Panel
- ALLOGEN AutoAntibody
- Amphiphysin Antibody IgG
- ANCA (Neutrophil Cytoplasmic Ab) Panel w/ Anti-MPO and PR3
- ANCA Profile (RDL)
- ANCA-Associated Vasculitis Profile (ANCA/MPO/PR3)
- Anti IgE
- Anti-C1q Antibody, IgG
- Anti-C1q Antibody, IgG
- Anti-Carbamylated Protein (CarP) Antibody
- Anti-CEP-1 Ab, IgG (RDL)
- Anti-cN-1A (NT5c1A) IBM
- Anti-cN-1A Ab (NT5c1A) IBM (RDL)
- Anti-Dense Fine Speckled Protein 70 kDa (DFS70) Ab
- Anti-EJ Ab (RDL)
- Anti-ENA6 Plus DFS70Ab Profile
- Anti-Fodrin Antibodies, IgG & IgA (RDL)
- Anti-Glomerular Basement Membrane Antibodies (RDL)
- Anti-GP-210 Ab (RDL)
- Anti-gp210 Antibody, IgG
- Anti-HMGCR Ab
- Anti-Ku Ab (RDL)
- Anti-MCV Antibody
- Anti-MDA-5 Ab (CADM-140) (RDL)
- Anti-Mi-2 Ab (RDL)
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation