Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Lymphoma (Aggressive) Panel by FISH

Lymphoma (Aggressive) Panel by FISH: ARUP Laboratories test 2002650

ARUP Laboratories test 2002650, CPT 88271, 88275. Specimen: Nondiluted bone marrow collected in a heparinized syringe. Also acceptable: Green (sodium heparin) tube.. Turnaround: 3-9 days.

Lymphoma (Aggressive) Panel by FISH is ARUP Laboratories test code 2002650, billed with CPT 88271, 88275. Specimen: Nondiluted bone marrow collected in a heparinized syringe. Also acceptable: Green (sodium heparin) tube.. Turnaround time: 3-9 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2002650
CPT88271 x3; 88275 x3
LOINC—
SpecimenNondiluted bone marrow collected in a heparinized syringe. Also acceptable: Green (sodium heparin) tube.
Turnaround time3-9 days
Storage / transportRoom temperature.

Use

Aid in the diagnosis of aggressive large B-cell lymphoma with intermediate features between Burkitt lymphoma and diffuse large B-cell lymphoma (DLBCL) and confirmation of suspected double-hit lymphoma. Reflex testing is available; refer to Aggressive B-Cell Lymphoma Reflex Panel by FISH, Tissue ( 3001495 ).

Methodology

Fluorescence in situ Hybridization (FISH)

Collection instructions

Transfer 3 mL bone marrow to a green (sodium heparin) tube (Min: 1 mL). OR transport 5 mL whole blood (Min: 2 mL)

Stability

Ambient: 48 hours; Refrigerated: 48 hours; Frozen: Unacceptable

Causes for rejection

Frozen specimens. Paraffin-embedded specimens. Clotted specimens.

Reference range

Refer to report

Remarks

Clinical indication or reason for testing and specimen type required with test order. Sample will still be processed if this information is not initially provided but appropriate culturing and reporting may be compromised or delayed.

Performed

Sun-Sat

Compliance Category

Analyte Specific Reagent (ASR)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2002651Lymphoma (Aggressive) Panel by FISH
2002652EER Lymphoma (Aggressive) Panel by FISH

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 88271, 88275

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation