Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Chromosome Analysis, Solid Tumor

Chromosome Analysis, Solid Tumor: ARUP Laboratories test 2002296

ARUP Laboratories test 2002296, CPT 88239, 88264. Specimen: Thaw media prior to tissue inoculation. Collect a 10mm solid tumor tissue biopsy (minimum of 5mm) in a sterile, screw-to. Turnaround: 14-28 days.

Chromosome Analysis, Solid Tumor is ARUP Laboratories test code 2002296, billed with CPT 88239, 88264. Specimen: Thaw media prior to tissue inoculation. Collect a 10mm solid tumor tissue biopsy (minimum of 5mm) in a sterile, screw-top container filled w. Turnaround time: 14-28 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2002296
CPT88239; 88264
LOINC11526-1, 62357-9
SpecimenThaw media prior to tissue inoculation. Collect a 10mm solid tumor tissue biopsy (minimum of 5mm) in a sterile, screw-top container filled with tissue culture transport medium.
Turnaround time14-28 days
Storage / transportRoom temperature.

Also known as: Karyotype

Use

May identify additional, useful cytogenetic abnormalities in tissues that are not targeted by FISH assays. For lymph node sample, order Chromosome Analysis, Lymph Node ( 2002300 )

Methodology

Giemsa Band

Collection instructions

DO NOT FREEZE. Do not place in formalin. Transport a 10 mm solid tumor tissue biopsy in a sterile, screw-top container filled with tissue culture transport medium (Min: 5 mm).

Stability

Ambient: 48 hours; Refrigerated: 48 hours; Frozen: Unacceptable

Causes for rejection

Frozen specimens. Specimens preserved in formalin.

Reference range

Refer to report

Remarks

Clinical indication or reason for testing and specimen type required with test order. Sample will still be processed if this information is not initially provided but appropriate culturing and reporting may be compromised or delayed. Indicate if patient has received a bone marrow transplant and specify sex of donor.

Performed

Sun-Sat

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0097778Chromosome Analysis, Solid Tumor62357-9
2002210EER Chromosome Analysis, Solid Tumor11526-1

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 88239, 88264

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation