Lymphocyte Antigen and Mitogen Proliferation Panel: ARUP Laboratories test 0096056
ARUP Laboratories test 0096056, CPT 86353. Specimen: Green (sodium heparin) (patient) AND green (sodium heparin) (control). Also acceptable: Yellow (ACD solution A) (patient. Turnaround: 9-10 days.
Also known as: Antigen & Mitogen Proliferation Panel; Blastogenesis Antigens; Blastogenesis Mitogens; Lymphocyte Blastogenesis; Lymphocyte Blastogenesis Antigens; Mitogen Studies
Use
Use to evaluate patients with suspected immunodeficiency diseases, including severe combined immunodeficiency. Do not order for patients younger than 3 months unless clinical history of candidiasis is present. For patients who are lymphopenic, collection of 10 mL of whole blood, rather than the minimum required volumes, is recommended to increase the likelihood that a sufficient number of lymphocytes can be isolated for testing.
Methodology
Cell Culture
Collection instructions
Transport 10 mL whole blood (patient) AND 10 mL whole blood (control) in original collection tubes. (Min: 7 mL (patient) AND 7 mL (control)) Do not refrigerate or freeze. LIVE LYMPHOCYTES REQUIRED. Infant Minimum: 3 mL (patient) AND 7 mL (control). For patients who are lymphopenic, collection of 10 mL of whole blood, rather than the minimum required volumes, is recommended to increase the likelihood that a sufficient number of lymphocytes can be isolated for testing.
Stability
Ambient: 48 hours; Refrigerated: Unacceptable; Frozen: Unacceptable New York State Clients: Ambient 24 hours; Refrigerated: Unacceptable; Frozen: Unacceptable
Patient preparation
Collect control specimen from a healthy individual unrelated to patient at approximately the same time as and under similar conditions to the patient.
Causes for rejection
Yellow (ACD solution B). Refrigerated or frozen specimens. Specimens in transport longer than 48 hours.
Reference range
Refer to report
Performed
Sun, Tue, Wed, Thu, Fri, Sat
Compliance Category
Laboratory Developed Test (LDT)
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 0096056 | Lymphocyte Ag and Mitogen Panel | 59063-8 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 86353
- Antigen-induced Lymphocyte Proliferation Panel (Candida, Tetanus, TB PPD)
- Beryllium Lymphocyte Proliferation, Blood
- LPT to Beryllium, BAL
- LPT to Beryllium, Blood
- Lymphocyte Antigen Proliferation
- Lymphocyte Mitogen Proliferation
- Lymphocyte Proliferation Antigens
- Lymphocyte Proliferation Mitogens
- Lymphocyte Transformation Test to Candida Antigen
- Mitogen LTT
- Toll-Like Receptor Function
- Beryllium Lymphocyte Stimulation Test
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation