Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Allergens, Inhalants, Environmental Profile 10

Allergens, Inhalants, Environmental Profile 10: ARUP Laboratories test 0055305

ARUP Laboratories test 0055305, CPT 86003, 86005. Specimen: Serum separator tube. Multiple specimen tubes should be avoided.. Turnaround: 1-3 days.

Allergens, Inhalants, Environmental Profile 10 is ARUP Laboratories test code 0055305, billed with CPT 86003, 86005. Specimen: Serum separator tube. Multiple specimen tubes should be avoided.. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0055305
CPT86003 x9; 86005
LOINC31161-3, 48767-8, 6020-2, 6025-1, 6075-6, 6095-4, 6096-2, 6098-8
SpecimenSerum separator tube. Multiple specimen tubes should be avoided.
Turnaround time1-3 days
Storage / transportRefrigerated.

Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Collection instructions

Separate serum from cells ASAP or within 2 hours of collection. Transfer 1.15 mL serum to an ARUP Standard Transport Tube. (Min: 0.6 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Patient preparation

Multiple patient encounters should be avoided.

Causes for rejection

Hemolyzed, icteric, or lipemic specimens.

Reference range

Allergens included: Alternaria alternata (tenuis) , Aspergillus fumigatus , Cat Epithelium & Dander, D. farinae (Mites), D. pteronyssinus (Mites), Dog Dander, Feather Mix, Hormodendrum ( Cladosporium ), House Dust Greer, Penicillium notatum . Effective 02/18/2014 Reporting Range (reported in kU/L) Probability of IgE Mediated Clinical Reaction Class Scoring Less than 0.10 No significant level detected 0 0.10 - 0.34 Clinical relevance undetermined 0/1 0.35 - 0.70 Low 1 0.71 - 3.50 Moderate 2 3.51 - 17.50 High 3 17.51 - 50.00 Very high 4 50.01 - 100.00 Very high 5 Greater than 100.00 Very high 6

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0055001Allergen, Fungi/Mold, A. alternata IgE6020-2
0055006Allergen, Animal, Cat Dander IgE6833-8
0055037Allergen, Animal, Feather Mix IgE31161-3
0055038Allergen, Fungi/Mold, Hormodendrum IgE6075-6
0055041Allergen, Interp, Immunocap Score IgE48767-8
0055061Allergen, Fungi/Mold, A. fumigatus IgE6025-1
0055063Allergen, Mites, D. pteronyssinus IgE6096-2
0055064Allergen, Mites, D. farinae IgE6095-4
0055080Allergen, Fungi/Mold, P. notatum IgE6212-5
0055091Allergen, House Dust Greer IgE9828-5
0099568Allergen, Animal, Dog Dander IgE6098-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86003, 86005

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation