Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Cytomegalovirus Antibody, IgM

Cytomegalovirus Antibody, IgM: ARUP Laboratories test 0050553

ARUP Laboratories test 0050553, CPT 86645. Specimen: Serum separator tube (SST).. Turnaround: Within 24 hours.

Cytomegalovirus Antibody, IgM is ARUP Laboratories test code 0050553, billed with CPT 86645. Specimen: Serum separator tube (SST).. Turnaround time: Within 24 hours. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0050553
CPT86645
LOINC7853-5
SpecimenSerum separator tube (SST).
Turnaround timeWithin 24 hours
Storage / transportRefrigerated.

Also known as: CMV IgM; CMV Antibody; CMV

Use

Not recommended as a standalone test. If using serologic testing, IgM combined with IgG is preferred; refer to Cytomegalovirus Antibodies, IgG and IgM ( 0050622 ). Do not use for diagnosis in immunocompromised individuals. Preferred test to detect CMV infection is Cytomegalovirus by Quantitative NAAT, Plasma ( 3005895 ).

Methodology

Semi-Quantitative Chemiluminescent Immunoassay (CLIA)

Collection instructions

Allow specimen to clot completely at room temperature. Separate from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.5 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens.

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (Avoid repeated freeze/thaw cycles)

Causes for rejection

Contaminated, heat-inactivated, icteric, or grossly hemolyzed specimens.

Reference range

29.9 AU/mL or less: Not Detected. 30.0-34.9 AU/mL: Indeterminate - Repeat testing in 10-14 days may be helpful. 35.0 AU/mL or greater: Detected - IgM antibody to CMV detected, which may indicate a current or recent infection. However, low levels of IgM antibodies may occasionally persist for more than 12 months post-infection.

Remarks

Label specimens plainly as "acute" or "convalescent."

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050553CMV Antibody IgM7853-5

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86645

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.