Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › CLL full panel by FISH

CLL full panel by FISH: Allina Health Laboratory (Abbott Northwestern) test Order the individual components; 4280H (blood) or 4280G (bone marrow)

Allina Health Laboratory (Abbott Northwestern) test Order the individual components; 4280H (blood) or 4280G (bone marrow), CPT 88271, 88275. Specimen: Sodium heparin (Na hep) whole blood. Turnaround: 5 - 7 days.

CLL full panel by FISH is Allina Health Laboratory (Abbott Northwestern) test code Order the individual components; 4280H (blood) or 4280G (bone marrow), billed with CPT 88271, 88275. Specimen: Sodium heparin (Na hep) whole blood. Turnaround time: 5 - 7 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test codeOrder the individual components; 4280H (blood) or 4280G (bone marrow)
CPT88271 x 8; 88275 x 4; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSodium heparin (Na hep) whole blood
Volume4 mL
Minimum volume2.0 mL
ContainerDk green Sodium heparin (Na hep), no gel
Turnaround time5 - 7 days

Also known as: ATM deletion; CCND1/IGH; CLL; Chronic Lymphocytic Leukemia; Deletion 6q21; MYC rearrangement; SLL; Small Lymphocytic lymphoma; t(11;14); Trisomy 12; TP53 deletion; 8q24; 11p22 deletion; +12; 13q14.3 deletion; 13q deletion; 17p13.1 deletion; Tests included:; 6q21; ATM; CCND1; CEP12; DEL13; IGH; MYC; TP53

Use

Detecting the prognostically significant cytogenetics FISH abnormalities used in the CLL/SLL NCCN guidelines

Methodology

Fluorescence in situ hybridization (FISH)

Collection instructions

Only one specimen tube is required to perform all ordered cytogenetics testing. The more testing ordered, the closer to the optimal volume requirements is preferred.

Stability

Ambient

Causes for rejection

Improper label (unlabeled or mislabeled) Wrong container (anticoagulant or solution) Improper blood/anticoagulant ratio Delay in transport Improper storage Leaking container

Reference range

Normal or Abnormal with interpretation

Performed

As needed

Order number

LAB4280H - CYTOGENETIC LEUKEMIC BLOOD STUDIES LAB4280G - CYTOGENETIC BONE MARROW STUDIES

Alternate container

EDTA whole blood (not recommended) Lavender (EDTA), 4mL Alternate specimen volume: Bone marrow: 10 mL (minimum 5 mL) Alternate collection instructions: Bone marrow Collect bone marrow aspirate in a sterile Sodium heparin (Na hep) syringe and transfer to a sterile vial/tube - or - Collect bone marrow in sterile syringe (non-heparinized) and transfer to a Dk green Sodium heparin (Na hep), no gel Alternate transport container: Bone marrow: Sterile vial/tube Dk green Sodium heparin (Na hep), no gel EDTA whole blood: Lavender (EDTA), 4mL Required forms/information: AHL Cytogenetics oncology request

Alternate specimens

Bone marrow EDTA whole blood (a chromosome analysis study is not recommended for this specimen type)

Transport container

Dk green Sodium heparin (Na hep), no gel

Performing Laboratory

AHL - Cytogenetics: X

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88271, 88275

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation