Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Thyroid stimulating hormone with reflex to free T4

Thyroid stimulating hormone with reflex to free T4: Allina Health Laboratory (Abbott Northwestern) test 8960

Allina Health Laboratory (Abbott Northwestern) test 8960, CPT 84439, 84443. Specimen: Lithium heparin (Li hep) plasma. Turnaround: 1 day.

Thyroid stimulating hormone with reflex to free T4 is Allina Health Laboratory (Abbott Northwestern) test code 8960, billed with CPT 84439, 84443. Specimen: Lithium heparin (Li hep) plasma. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories, OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code8960
CPT84443; 84439 (if appropriate); Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenLithium heparin (Li hep) plasma
Volume2.0 mL
Minimum volume0.2 mL
ContainerLt green plasma separator (PST)
Turnaround time1 day

Also known as: Thyrotropin; Thyrotropic hormone; Tests included:; Any TSH value of 4.94 µIU/mL will automatically reflex to a Free T4 at an additional charge

Use

This reflex test was established on the recommendation of the Clinical Practice Council to be the preferred first lab test ordered in the screening for thyroid disease. Any TSH value of <0.35 or >4.94 µIU/mL will automatically reflex to a Free T4. Providers also have the ability to order each of these tests (TSH and FT4) individually.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

Immediately follow collection, mix sample by inverting 8 - 10 times to prevent clotting

Stability

Refrigerated (preferred) - 7 days Frozen - 6 months Ambient - NO

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Inappropriate timing of collection Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

0.270 - 4.20 µIU/mL

Performed

Daily

Abbreviation

TSR

Order number

LAB8960

Alternate container

Gold serum separator (SST) tube Red serum vial/tube, 5 mL Red serum vial/tube, 10 mL Alternate collection instructions: Immediatley following collection, mix sample by inverting 5 times Alternate processing instructions: Gold: Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection Red: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL), labelled as serum, within two (2) hours of sample collection Alternate transport container: Gold serum separator (SST) tube False bottom plasma/serum transport vial/tube (AHL)

Alternate specimens

Serum

Transport container

Lt green plasma separator (PST)

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Spin within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 84439, 84443

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation