Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Immature platelet fraction

Immature platelet fraction: Allina Health Laboratory (Abbott Northwestern) test 8931

Allina Health Laboratory (Abbott Northwestern) test 8931, CPT 85055. Specimen: EDTA whole blood. Turnaround: Routine - 1 day.

Immature platelet fraction is Allina Health Laboratory (Abbott Northwestern) test code 8931, billed with CPT 85055. Specimen: EDTA whole blood. Turnaround time: Routine - 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, OHSU Laboratory Services, Michigan Medicine Laboratories (MLabs).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code8931
CPT85055
LOINC—
SpecimenEDTA whole blood
Volume5.0 mL
ContainerLavender (EDTA), 4mL
Turnaround timeRoutine - 1 day Available STAT

Also known as: Reticulated platelet

Use

Differential diagnosis of thrombocytopenia Monitoring bone marrow recovery after chemotherapy or stem cell transplantation Risk stratification in acute coronary syndromes Monitoring the effect of treatment with antiplatelet drugs in patients with coronary artery diseases

Methodology

Sysmex

Collection instructions

Immediately following collection, mix sample thoroughly by gently inverting 8 - 10 times, to prevent clotting

Stability

Refrigerated (preferred) - 48 hours Ambient (OK) - 24 hours

Causes for rejection

Improper label (unlabeled or mislabeled) Clotted specimen Improper anticoagulant or ratio Hemolysis Delay in transport Improper storage/transport temperature

Reference range

0.9 - 11.2%

Performed

Daily

Abbreviation

IPF

Order number

LAB8931

Transport container

Lavender (EDTA), 4mL

Performing Laboratory

AHL - Hematology: H

Processing instructions

Submit entire specimen; do not spin

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85055

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation