Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Anaerobic culture

Anaerobic culture: Allina Health Laboratory (Abbott Northwestern) test 6554

Allina Health Laboratory (Abbott Northwestern) test 6554, CPT 87075, 87077, 87186. Turnaround: Preliminary: 2-3 days.

Anaerobic culture is Allina Health Laboratory (Abbott Northwestern) test code 6554, billed with CPT 87075, 87077, 87186. Turnaround time: Preliminary: 2-3 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories, Quest Diagnostics.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code6554
CPT87075; Additional CPT codes (if appropriate):; 87186 - Sensitivities; 87077 - ID; This list may not be all inclusive if there is the need to send the ID or sensitivities out to a referral laboratory
LOINC—
ContainerSwab: ESwab standard tip collection kit (white) F luid: Capped Syringe without needle. Expel excess air. Tissue: ESwab standard tip collection kit (white) in the liquid without the swab
Turnaround timePreliminary: 2-3 days Final: 5 - 14 days

Methodology

Culture

Collection instructions

Anaerobes are part of the endogenous flora of the body, so it is important to culture only specimen from sites that do not have normal anaerobic flora (refer to reasons for rejection). Sources appropriate for anaerobic culture include: Abscess aspirate (including rectal, oral and vaginal), body fluid, bronchoscopy, Cerebral spinal fluid (CSF), IUD for Actinomyces species, placental tissue from C-section delivery, sinus aspirate/swab, surgical specimens not contaminated with bowel flora, tissue, transtracheal aspirate or urine collected by suprapubic aspirate. Swab Collection Open and remove the tube and swab applicator. Collect specimen. Do not touch the area below the red breakpoint line. Aseptically remove cap from tube. Insert swab into tube and bend shaft against tube at colored line to break shaft. Replace cap on the tube and secure tightly. Label specimen with patient’s name, ID#, specimen source, and date and time of collection. Needle Aspiration Using aseptic technique, aspirate specimen with a sterile syringe and needle. Remove needle and expel air from syringe. Label specimen with patient’s name, ID#, specimen source, and date and time of collection. Tissue Collection Open and remove the ESwab transport tube. The ESwab applicator is not needed. Aseptically remove cap from tube. Using aseptic technique, place the tissue in the liquid in the transport tube. Replace cap on the tube and secure tightly. Label specimen with patient’s name, ID#, specimen source, and date and time of collection.

Stability

Capped syringe: Ambient - 24 hours ESwab: Ambient (preferred) - 48 hours Refrigerated - 48 hours

Causes for rejection

Improper label (unlabeled or mislabeled) Time delay between time of collection and receipt of specimen Inappropriate timing of collection Improper transport container Improper transport temperature Interfering substances Inappropriate specimen type Colostomy discharge Decubitus ulcer Fecal/rectal swab Foley cath tips Lochia Oral swab Skin swab Sputum BAL or bronchoscopy specimens NOT collected by protected brush Prostatic or seminal fluid Specimens from sites contaminated with fecal flora Superficial wound specimens Throat, nasal or nasopharyngeal (NP) swabs Urethral secretions Vaginal/cervical swabs Voided or catheterized urine Swabs not in anaerobic transport media Leaking container

Performed

Daily

Abbreviation

ANC Tests included: Identification, susceptibilities and serogrouping will be performed on all microbiology isolates considered by the laboratory to be significant.

Order number

87075.0

Alternate container

Swab: ESwab flexible mini-tip collection kit (blue) ESwab mini-tip collection kit (green) Tissue: E swab mini-tip collection kit (blue or green) in the liquid without the swab Alternate transport container: Swab: ESwab transport tube (blue or green) Tissue: ESwab transport tube (blue or green) in the liquid without the swab

Transport container

Swab: ESwab transport tube Fluid: Capped Syringe without needle. Tissue: ESwab transport tube in the liquid without the swab

Performing Laboratory

AHL - Microbiology: M

Processing instructions

Specimen MUST be in ESwab or anaerobic transport media. Allina Health metro hospital collections may be sent directly to the lab in a capped syringe (no needles) with air expressed out within one hour of collection. Notes: If specimen quantity is limited, the entire specimen can be placed in the anaerobic container. Aerobic, anaerobic, fungus and AFB cultures can all be performed on specimens in anaerobic transport containers. Order Anaerobic Culture and the appropriate aerobic culture (ex, Body Fluid Culture, Tissue Culture, etc.)

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 87075, 87077, 87186

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation