Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Antibody identification

Antibody identification: Allina Health Laboratory (Abbott Northwestern) test 6067

Allina Health Laboratory (Abbott Northwestern) test 6067, CPT 86870. Specimen: EDTA whole blood and serum clot tube. Turnaround: 1 - 3 days.

Antibody identification is Allina Health Laboratory (Abbott Northwestern) test code 6067, billed with CPT 86870. Specimen: EDTA whole blood and serum clot tube. Turnaround time: 1 - 3 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: OHSU Laboratory Services, Labcorp, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code6067
CPT86870
LOINC—
SpecimenEDTA whole blood and serum clot tube
Volume8mL EDTA whole blood and 2 clot tubes
ContainerTwo (2) Lavender (EDTA), 4mL and Two (2) Red serum vial/tube, 10 mL tubes
Turnaround time1 - 3 days

Methodology

Column-agglutination Agglutination

Collection instructions

Sample should be obtained no more than 3 days (up to 96 hours) prior to testing. In certain circumstances, additional blood may be requested to complete testing. If the patient has a known antibody, collect and submit 2-3 4mL EDTA whole blood tubes for testing. Lavender: Immediatley following collection, mix sample by inverting 8 - 10 times to prevent clotting. Labelling instructions: Excellian sites: Tube must be labeled with the patients first and last name and Excellian MRN, date and time of collection and phlebotomist’s A# Non-Excellian sites: Tube must be labeled with the patient's first and last name and date of birth, date and time of collection and phlebotomist’s initials.

Stability

Refrigerated - 3 days (96 hrs)

Causes for rejection

Improper label (unlabeled or mislabeled) Hemolysis

Reference range

Negative If positive : Specifictiy of the alloantibody (ies) will be stated. The patient's red blood cells may be typed for the corresponding antigens or as an aid to identificaton in complex cases.

Performed

Daily

Abbreviation

ABI Tests included: Positive results will reflex to additional testing

Order number

86870.06

Transport container

Two (2) Lavender (EDTA), 4mL tubes and Two (2) Red serum vial/tubes, 10mL

Performing Laboratory

AHL - Blood Bank: B

Processing instructions

Submit all tubes unspun

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86870

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation