Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › TRA/D rearrangement FISH

TRA/D rearrangement FISH (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=4091Ddc5 8483 4C7F 85Cd E5875Dc831F9): Allina Health Laboratory (Abbott Northwestern) test 4280G (bone marrow), 4280H (blood)

Allina Health Laboratory (Abbott Northwestern) test 4280G (bone marrow), 4280H (blood). Specimen: Bone Marrow aspirate. Turnaround: 5 days.

TRA/D rearrangement FISH is Allina Health Laboratory (Abbott Northwestern) test code 4280G (bone marrow), 4280H (blood). Specimen: Bone Marrow aspirate. Turnaround time: 5 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code4280G (bone marrow), 4280H (blood) (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=4091Ddc5 8483 4C7F 85Cd E5875Dc831F9)
CPT88271x2; 88275x1; 88291x1; Subject to medical necessity (Y/N):; Yes
LOINC—
SpecimenBone Marrow aspirate
Volume5 mL
Minimum volume3 mL
ContainerSterile Sodium heparinized (Na hep) syringe transferred to a sterile vial/tube or Sterile syringe (non-heparinized) transferred to a Dk green Sodium heparin (Na Hep) tube, no gel
Turnaround time5 days

Also known as: T-Cell Gene; T-Cell Disorder; T-Cell Acute Lymphoblastic Leukemia; T Cell; 14q11.2 rearrangement

Use

Detecting rearrangements at 14q11.2 in T-ALL This test can be ordered individually or as part of a T Cell panel (see the individual panel tests for more details).

Methodology

Fluorescence in situ hybridization (FISH)

Collection instructions

Transfer aspirate from syringe to transport container.

Stability

Ambient Specimen retention time: Specimens retained until completion of all testing

Causes for rejection

Improper label (unlabeled or mislabeled) Wrong container (anticoagulant or solution) Delay in transport Improper storage Leaking container Slides broken beyond repair

Reference range

Normal or Abnormal with interpretation

Performed

M - F

Abbreviation

TRA/D

Order number

LAB4280G - CYTOGENETIC BONE MARROW STUDIES LAB4280H - CYTOGENETIC LEUKEMIC BLOOD STUDIES

Alternate container

Bone Marrow Core Submitted in sterile tube/cup filled with sterile culture medium, sterile Hanks Balance Salt Solution (HBSS) or sterile saline. Whole Blood Dk green Sodium heparin (Na hep), no gel Alternate specimen volume: Bone Marrow Core - 10 mm Whole Blood - 5 mL Alternate collection instructions: Whole Blood Immediately following collection, mix sample thoroughly by gently inverting 8 - 10, times to prevent clotting. Alternate processing instructions: Bone Marrow Core Submit entire specimen Whole Blood Submit entire specimen unspun Alternate transport container: Bone Marrow Core Sterile tube/cup Whole Blood Dk green Sodium heparin (Na hep) tube, no gel Required forms/information: Cytogenetics Oncology Requisition

Alternate specimens

Bone Marrow Core Touch Prep Slides Whole blood

Transport container

Sterile vial/tube or Dk green Sodium heparin (Na hep), no gel

Performing Laboratory

AHL - Cytogenetics: X

Processing instructions

Submit entire specimen unspun.

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation