Ammonia: Allina Health Laboratory (Abbott Northwestern) test 27
Allina Health Laboratory (Abbott Northwestern) test 27, CPT 82140. Specimen: EDTA plasma. Turnaround: 1 day.
Also known as: NH3
Use
Ammonia, derived from the catabolism of amino acids and from the action of intestinal bacteria on dietary protein, is converted to urea in the liver hepatocytes and so rendered non-toxic. Studies have shown that excess ammonia can have a toxic effect on the central nervous system and clinical manifestations are typically neurological disturbances. Elevated levels of ammonia may be either due to "Inborn Errors of Metabolism", or secondary to other conditions. Inborn errors of metabolism are the major cause of elevated ammonia in infants and usually the result of urea cycle enzyme deficiencies. Inherited disorders affecting the metabolism of the dibasic amino acids (lysine and ornithine) and…
Methodology
Enzymatic
Collection instructions
Following collection, mix sample by inverting 8 - 10 times to prevent clotting Immediately place sample on ice
Stability
Frozen (preferred) - 3 days Refrigerated - 2 hours Ambient - 30 minutes
Causes for rejection
Hemolysis Erythrocytes contain approximately 3 times more ammonia than does plasma Specimens should not be repeatedly frozen and thawed Specimens should be free of particulate matter and red blood cells Improper labels (unlabeled or mislabeled) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Inappropriate timing of collection Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)
Reference range
Male 11 - 51 µmol/L Female 16 - 60 µmol/L Results that require action (critical): >110 µmol/L
Performed
Daily
Abbreviation
AMM
Order number
82140
Transport container
False bottom plasma/serum transport vial/tube (AHL)
Performing Laboratory
AHL - Chemistry: C
Processing instructions
Spin and transfer plasma to a False bottom plasma/serum transport vial/tube (AHL), labelled as EDTA plasma, within 30 minutes of collection . If separation is delayed, the results may be falsely elevated. If the specimen will not be tested within 1 hour of collection , the plasma must be frozen at <-20°C.
View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29
Other tests billed with CPT 82140
- Ammonia
- Ammonia
- Ammonia
- Ammonia Level, Plasma
- Ammonia, Plasma
- Ammonia, Plasma
- Ammonium, 24 hour, Urine
- Ammonium, 24-Hour Urine
- Ammonium, Random, Urine
- Litholink 24-Hour Urine, KS
- Supersaturation Profile, 24 Hour, Urine
Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.