Prealbumin: Allina Health Laboratory (Abbott Northwestern) test 2455
Allina Health Laboratory (Abbott Northwestern) test 2455, CPT 84134. Specimen: Serum. Turnaround: 1 day.
Also known as: TBPA; Transthyretin
Methodology
Immunoturbidimetric
Collection instructions
Immediately following collection, thoroughly mix sample by gently inverting 5 times
Stability
Refrigerated ( preferred ) - 6 months Ambient - 3 days Frozen - 1 year
Causes for rejection
Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)
Reference range
20.0 - 40.0 mg/dL
Performed
Daily
Abbreviation
PRE
Order number
84134.0
Alternate container
Red serum vial/tube, 5 mL Alternate processing instructions: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL) , labelled as serum, within two (2) hours of sample collection Alternate transport container: False bottom plasma/serum transport vial/tube (AHL)
Transport container
Gold serum separator (SST) tube
Performing Laboratory
AHL - Chemistry: C
Processing instructions
Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection
View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29
Other tests billed with CPT 84134
Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation