Blood gases, venous: Allina Health Laboratory (Abbott Northwestern) test 201

Allina Health Laboratory (Abbott Northwestern) test 201. Specimen: Heparin whole blood, venous. Turnaround: 1 day.

Blood gases, venous is Allina Health Laboratory (Abbott Northwestern) test code 201. Specimen: Heparin whole blood, venous. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code201
CPT—
LOINC—
SpecimenHeparin whole blood, venous
Volume2.0 mL
ContainerBlood gas syringe
Turnaround time1 day

Also known as: VBG; Tests included:; pH; PCO 2; PO 2; HCO 3; Base excess; O 2 saturation

Use

Blood gas testing is used to evaluate respiratory diseases, conditions that affect the lungs, determine the effectiveness of oxygen therapy, and provide information about the body's acid / base balance, which can reveal important clues about lung and kidney function and the body's general metabolic state.

Methodology

Ion selective electrodes

Collection instructions

Warning: Should be collected at a hospital site Must arrive in lab within 30 minutes. Expel all air from the sample

Stability

Time sensitive Ambient - 30 minutes Vacutainer collection tubes submitted for venous blood gas analysis cannot be sent through the Pneumatic tube system (PTS)

Causes for rejection

Clotted specimens Insufficient quantity Incorrect anticoagulant (anything other than lithium heparin) or contaminated Specimens that do not meet transportation and storage requirements Specimen that has been exposed to air or contains air bubbles Specimen received in a plasma separator (PST) tube Improper labels (unlabeled or mislabeled) Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

Venous blood gas reference ranges Component Reference range pH, venous 7.32-7.43 pCO 2 , venous 41-51 mmHg pO 2 , venous 34-50 mmHg (0-<1 day) 34-40 mmHg (1 day - >1 mo) 35-40 mmHg (≥1 mo) HCO 3 , venous 22-29 mmol/L Base excess -2.0 - 3.0 O 2 saturation, venous 40.0-70.0 % (<1 day) 70-75 % (≥1 day)

Limitations

Vacutainer tubes are not anaerobic and it can result in an elevated pO2 if not handled properly

Performed

Daily

Abbreviation

BGV

Order number

82803.8

Alternate container

Dk green Lithium heparin (Li hep) Alternate collection instructions: Immediately after collection, mix tube thoroughly by gentle inversion, 8 - 10 times, to prevent clotting. The tube should be fully filled, unopened, and must arrive at AHL Central lab within 30 minutes of collection. Alternate processing instructions: Do not spin and do not open Alternate transport container: Dk green Lithium heparin (Li hep)

Transport container

Blood gas syringe

Performing Laboratory

AHL - Chemistry: C

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation