Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Alpha-fetoprotein tumor marker, serum

Alpha-fetoprotein tumor marker, serum: Allina Health Laboratory (Abbott Northwestern) test 20

Allina Health Laboratory (Abbott Northwestern) test 20, CPT 82105. Specimen: Serum. Turnaround: 2 days.

Alpha-fetoprotein tumor marker, serum is Allina Health Laboratory (Abbott Northwestern) test code 20, billed with CPT 82105. Specimen: Serum. Turnaround time: 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Quest Diagnostics.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code20
CPT82105; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSerum
Volume1.0 mL
Minimum volume0.5 mL
ContainerGold serum separator (SST) tube Red serum vial/tube, 5 mL
Turnaround time2 days

Also known as: AFP; Tumor marker; Alpha fetoprotein

Use

The test method changed on 1/3/2023 . If this test has been used for serial monitoring, rebaselining is recommended. Rebaselining consists of 2 measurements, collected 3-6 weeks apart. The Roche Elecsys CEA assay is an electrochemiluminescence immunoassay "ECLIA" performed on the Roche Cobas "e" immunoassy analyzers. Values obtained with different assay methods may be different and cannot be used interchangeably. Limitations: Not for pregnant females Biotin supplements may cause clinically significant interference for this test assay. If interference is suspected, it is strongly recomended that biotin is discontinued for at least one week prior to retesting.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

Immediatley following collection, mix sample by inverting 5 times

Stability

Refrigerated (preferred) - 14 days Ambient - 5 days Frozen - 6 months

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Inappropriate timing of collection Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

≤ 8.3 ng/mL

Performed

Daily

Abbreviation

AFT

Order number

82105.0

Alternate container

Lt green plasma separator (PST) Alternate collection instructions: Immediately follow collection, mix sample by inverting 8 - 10 times to prevent clotting Alternate processing instructions: Spin within two (2) hours of sample collection Alternate transport container: Lt green plasma separator (PST)

Alternate specimens

Lithium heparin (Li hep) plasma

Transport container

Gold serum separator (SST) tube False bottom plasma/serum transport vial/tube (AHL)

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection Red: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL) , labelled as serum, within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82105

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation