Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Hepatitis C Virus, Rapid PCR

Hepatitis C Virus, Rapid PCR: Allina Health Laboratory (Abbott Northwestern) test 16005

Allina Health Laboratory (Abbott Northwestern) test 16005, CPT 87521. Specimen: EDTA whole blood, Fingerstick. Turnaround: STAT: 2.5 hours.

Hepatitis C Virus, Rapid PCR is Allina Health Laboratory (Abbott Northwestern) test code 16005, billed with CPT 87521. Specimen: EDTA whole blood, Fingerstick. Turnaround time: STAT: 2.5 hours. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN).
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code16005
CPT87521-QW; Subject to medical necessity (Y/N):; Yes; LOINC code:; 5010-4
LOINC—
SpecimenEDTA whole blood, Fingerstick
Volume500 µL
Minimum volume250 µL
ContainerMicrotainer - lavender (EDTA)
Turnaround timeSTAT: 2.5 hours Routine: 4 hours

Use

Rapid diagnosis of active Hepatitis C viral infection presenting at ANW, Mercy, United, or Unity hospital emergency departments with increased risk factors for HCV infection who otherwise may not be diagnosed and treated due to lack of primary care, housing insecurity/homelessness, substance abuse, and/or high-risk sexual behavior Limitations: Due to 4 hour stability this test cannot be collected at sites other than ANW-Main Campus, Mercy- Mercy and Unity campuses, and United – United Hospital campus. Assay cannot distinguish between acute and chronic states of infection. Specimens other than EDTA microtainer whole blood collected from a fingerstick may result in inaccurate…

Methodology

Real time PCR (RT-PCR)

Collection instructions

Gather collection supplies; Lancet (minimum 2 mm depth), Microtainer EDTA, alcohol wipe, gauze, bandage, warming pack. Warm patient’s hands with warm pack for 5-10 minutes. Hand should be warm to the touch. Failure to warm the hand may result in insufficient blood flow for collection. Have patient clench and unclench hand 10 times. Clean tip of middle or ring finger with alcohol and allow to dry. Uncap microtainer and place nearby. With patient’s palm facing the floor, firmly place lancet slightly to side of finger pad and trigger the lancet. Wipe first drop of blood with gauze pad. Keeping the finger in downward position, touch the open end of microtainer at 30-45 angle to the drop of blood. Gentle massage finger to maintain blood flow. Tap the microtainer between drops to move blood drops to bottom of container and avoid clotting. Fill microtainer until between the 250 and 500 marks. Recap the container securely. Mix the specimen by inverting at least 10 times. Have patient hold gauze on finger tip to stop bleeding. Followed by application of bandage.

Stability

Ambient - 15-30°C for up to 4 hours Specimen retention time: One week

Causes for rejection

Specimens other than whole blood collected in EDTA microtainer from fingerstick. Specimens received outside of the listed transport and stability requirements.

Reference range

Not Detected

Performed

Daily

Abbreviation

HCV PCR Tests included: HCV RAPID PCR

Order number

LAB16005

Performing Laboratory

AHL – Microbiology: M

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation