Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Ber-EP4 by IHC

Ber-EP4 by IHC (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=Ae8Ded10 F0B5 45E9 8806 9Ed8C5Ce679D): Allina Health Laboratory (Abbott Northwestern) test 12376 - Technical only, 12379 - Technical & interpretation

Allina Health Laboratory (Abbott Northwestern) test 12376 - Technical only, 12379 - Technical & interpretation, CPT 88341, 88342. Specimen: Tissue. Turnaround: 1 - 2 days.

Ber-EP4 by IHC is Allina Health Laboratory (Abbott Northwestern) test code 12376 - Technical only, 12379 - Technical & interpretation, billed with CPT 88341, 88342. Specimen: Tissue. Turnaround time: 1 - 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code12376 - Technical only, 12379 - Technical & interpretation (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=Ae8Ded10 F0B5 45E9 8806 9Ed8C5Ce679D)
CPT88342 - 1st stain; 88341 - each additional stain
LOINC—
SpecimenTissue
Turnaround time1 - 2 days

Use

Ber EP4 can be useful in a panel of immunostains to differentiate between mesothelioma and adenocarcinoma The majority of lung and other adenocarcinomas are reactive with Ber EP4 Mesotheliomas are usually negative for Ber EP4. However, 1-11% are reportedly positive for Ber EP4. Only one report to date showed a relatively high rate of positivity (20%) for mesotheliomas with Ber EP4 (see Gaffey et al) A staining pattern of CEA negative, Ber EP4 negative and LeuM1 (CD15) negative is said to be 100% specific for mesothelioma. (See Grove et al.) A staining pattern of Ber EP4 positive, CEA positive and LeuM1 positive is said to be 96.8% specific for adenocarcinoma (See Grove et al) Renal cell…

Methodology

Immunohistochemical staining and microscopic examination

Stability

Ambient (preferred)

Causes for rejection

Unlabeled/mislabeled block Insufficient tissue Slides broken beyond repair

Reference range

If requested, an interpretive report will be provided

Performed

Mo - Fr

Order number

LAB12376 LAB12379 Tests included: All IHC stains will include a positive control tissue

Transport container

Formalin-fixed, paraffin embedded (FFPE) tissue block Alternate transport container: Tissue section mounted on a charged, unstained slide

Performing Laboratory

AHL - Immunohistochemistry

Processing instructions

Submit a formalin-fixed, paraffin embedded tissue block

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88341, 88342

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation