Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › CD138 by IHC

CD138 by IHC (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=A9Cf5Ea9 1C50 4A91 85F6 904D1D7Dccef): Allina Health Laboratory (Abbott Northwestern) test 12376 - Technical only, 12379 - Technical & interpretation

Allina Health Laboratory (Abbott Northwestern) test 12376 - Technical only, 12379 - Technical & interpretation, CPT 88341, 88342. Specimen: Tissue. Turnaround: 1 - 2 days.

CD138 by IHC is Allina Health Laboratory (Abbott Northwestern) test code 12376 - Technical only, 12379 - Technical & interpretation, billed with CPT 88341, 88342. Specimen: Tissue. Turnaround time: 1 - 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code12376 - Technical only, 12379 - Technical & interpretation (View?Templateuid=Ff24F908 Cdc8 4068 84Eb 6Ce60783F288&Customobjectuid=A9Cf5Ea9 1C50 4A91 85F6 904D1D7Dccef)
CPT88342 - 1st stain; 88341 - each additional stain
LOINC—
SpecimenTissue
Turnaround time1 - 2 days

Also known as: Syndecan-1; Tests included:; All IHC stains will include a positive control tissue

Use

CD138 is a very useful marker in identifying plasma cells This antibody will identify plasmacytomas/multiple myeloma, plasmocytic lymphomas, and some cases of immunoblastic lymphoma with plasmacytoid differentiation CD138 can be used in a panel with bcl-6, to help divide the HIV associated lymphomas into those of follicular origin (bcl-6 + / CD138 -) and those of post-follicular origin (bcl-6 - / CD138 +) CD138 staining has been shown to be present in normal epidermis, squamous cell carcinoma in situ, and keratoacanthomas; in contrast, invasive squamous cell carcinomas show markedly reduced staining CD138 reactivity in plasmacytic and non-plasmacytic tumors 7 Diagnosis # cases Tumor…

Methodology

Immunohistochemical staining and microscopic examination

Stability

Ambient (preferred)

Causes for rejection

Unlabeled/mislabeled block Insufficient tissue Slides broken beyond repair

Reference range

If requested, an interpretive report will be provided

Performed

Mo - Fr

Order number

LAB12376 LAB12379

Transport container

Formalin-fixed, paraffin embedded (FFPE) tissue block Alternate transport container: FFPE tissue section mounted on a charged, unstained slide

Performing Laboratory

AHL - Immunohistochemistry

Processing instructions

Submit a formalin-fixed, paraffin embedded tissue block

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 88341, 88342

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation