PATHFAST Immunoanalyzer Operator Course
Operator training for the PATHFAST compact chemiluminescent immunoassay analyzer used for cardiac and other rapid markers.
Free45 min6 lessons10-question quiz
This course covers general operator principles for the PATHFAST. Always follow the manufacturer's current instructions for use and your lab's written procedures. Product names are trademarks of their owners; Sound Lab Consultants is not affiliated with the manufacturer.
Lessons
Lesson 1: About the analyzer
PATHFAST is a compact, cartridge-based immunoassay analyzer that uses chemiluminescent enzyme immunoassay with magnetic particle separation. It can run several samples in parallel channels and is used in emergency departments, urgent care and hospital labs for rapid markers such as cardiac troponin. Which assays you may run, and their CLIA complexity, depends on the FDA clearance of each assay: check the FDA CLIA database and your lab's test menu before running any assay.
Lesson 2: Specimens and preparation
- Use only the specimen types and anticoagulants listed in the assay package insert (commonly heparinized whole blood or plasma).
- Label every specimen with two patient identifiers, the collection date and time.
- Check for clots, hemolysis and insufficient volume; follow the insert's limits and reject or recollect as your policy states.
- Bring cartridges and reagents to the temperature the insert requires before use.
Lesson 3: Running a test
- Confirm daily checks, maintenance and QC are current.
- Enter or scan the patient and sample ID.
- Load the assay cartridge, tip and sample in the positions shown in the IFU.
- Start the run and do not open the instrument while it is processing.
- Review the result and any flags before release; follow the IFU for error codes.
Lesson 4: Calibration and quality control
Calibration information is lot-specific and supplied by the manufacturer for each reagent lot. Follow the IFU for how calibration is entered and verified.
Quality control (QC) proves the test system is working before you report patient results. Run QC at the frequency required by the manufacturer, CLIA (42 CFR 493.1256) and your lab's policy, and whenever you open a new reagent lot or shipment, after major maintenance, and after troubleshooting. Many labs use an Individualized Quality Control Plan (IQCP) for eligible non-waived tests; if yours does, follow the frequencies written in it.
- Record every QC result, the lot numbers and expiration dates, and who ran it.
- Do not report patient results when QC is out of range. Stop, troubleshoot, document corrective action, rerun QC, and review patient results since the last acceptable QC.
- Store controls and reagents at the temperatures on the package insert and never use them past their expiration date.
Lesson 5: Maintenance and troubleshooting
- Perform and document daily, weekly and as-needed maintenance exactly as the IFU lists.
- Keep the analyzer clean with the disinfectant the manufacturer approves.
- For repeated errors, stop testing, record the error code, follow the troubleshooting guide and contact technical support. Document the corrective action.
Lesson 6: Reporting and competency
- Identify the patient with at least two identifiers before collecting or testing.
- Report results with units and reference ranges, and follow your lab's critical value policy: notify the responsible provider promptly and document who was told, when, and read-back.
- Correct errors with a documented corrected report; never erase or overwrite original records.
- Keep test records, QC and maintenance logs for at least 2 years (longer where your state or accreditor requires).
Under CLIA, everyone who performs non-waived testing must have documented training before reporting patient results, and documented competency assessment at 6 months and 12 months in the first year and annually after that. The six required methods are direct observation of routine testing, monitoring of recording and reporting of results, review of worksheets, QC and maintenance records, direct observation of maintenance and function checks, testing of previously analyzed or external samples, and assessment of problem-solving skills (42 CFR 493.1451 and 493.1413). Waived testing follows the manufacturer's instructions and your lab's own training and competency policy.
This course documents training. It does not replace the competency assessment your laboratory director or technical consultant must perform at your site.
Quiz and certificate
Answer all 10 questions. Score 80% or higher to get your free certificate from Sound Lab Consultants - Technical Consultants.
Under CLIA, everyone who performs non-waived testing must have documented training before reporting patient results, and documented competency assessment at 6 months and 12 months in the first year and annually after that. The six required methods are direct observation of routine testing, monitoring of recording and reporting of results, review of worksheets, QC and maintenance records, direct observation of maintenance and function checks, testing of previously analyzed or external samples, and assessment of problem-solving skills (42 CFR 493.1451 and 493.1413). Waived testing follows the manufacturer's instructions and your lab's own training and competency policy. This course documents training. It does not replace the competency assessment your laboratory director or technical consultant must perform at your site.