STI PCR Panel
An STI PCR panel uses nucleic acid amplification to test one urine or swab specimen for several sexually transmitted infections at once, most commonly chlamydia, gonorrhea and trichomonas, with Mycoplasma genitalium and herpes (HSV-1/2) added on expanded panels. Blood tests for HIV, syphilis and hepatitis are run separately on serum.
- Specimen
- Urine, vaginal, endocervical, urethral, rectal and throat swabs, depending on the assay's clearance.
- CLIA complexity
- Moderate to high, depending on the test system
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87491 / 87591 / 87661 / 87563, 87529, 87801
How it works
- One specimen: Urine or a vaginal, rectal or throat swab is collected in a single transport tube.
- Multiplex NAAT: Several targets are amplified together or on the same platform.
- Organism-level report: Each organism is reported separately so treatment and partner notification are specific.
Typical STI panel tiers
| Panel | Typical targets |
|---|---|
| Basic | Chlamydia, gonorrhea |
| Standard | Chlamydia, gonorrhea, trichomonas |
| Expanded | Adds Mycoplasma genitalium, HSV-1/2 (lesions), Ureaplasma/M. hominis on some LDTs |
| Blood (separate) | HIV-1/2 Ag/Ab, syphilis, hepatitis B and C |
Specimen collection
- Urine, vaginal, endocervical, urethral, rectal and throat swabs, depending on the assay's clearance.
Accuracy, results and interpretation
- Ureaplasma and Mycoplasma hominis are common colonizers; CDC does not recommend routine testing for them, and payers often deny them.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Automated platforms | Panther (Aptima), cobas 6800/8800, Alinity m STI, BD MAX/COR | High |
| Cartridge | Xpert CT/NG, Xpert TV | Moderate |
| LDT multiplex | Open qPCR panels | High |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87491 / 87591 / 87661 / 87563 | CT, NG, trichomonas and M. genitalium amplified probe |
| 87529 | HSV amplified probe |
| 87801 | Multiple organisms, amplified probe (payer-specific) |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Build panels around CDC guidelines and payer policies; panels padded with low-value targets invite denials and audits.
- Each target reported needs to be validated and covered by proficiency testing or twice-yearly alternative assessment.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering STI PCR panel
Bringing STI PCR panel in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Does an STI PCR panel include HIV and syphilis?
No. HIV and syphilis are diagnosed with blood tests. A full STI screen usually combines a PCR panel with HIV and syphilis serology.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.