Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultants › Lab test guides › Syphilis test (RPR and treponemal)

Syphilis Test

Reviewed November 28, 2026 by the Sound Lab Consultants laboratory team · Syphilis serology (CLIA diagnostic immunology)

Short answer

Syphilis is diagnosed with two types of blood tests: a nontreponemal test (RPR or VDRL), whose titer reflects disease activity and falls with treatment, and a treponemal antibody test (EIA/CIA, TP-PA or FTA-ABS), which usually stays positive for life. A positive result on one type is confirmed with the other, using either the traditional or the reverse sequence algorithm.

Specimen
Serum (or plasma per the assay).
CLIA complexity
Waived to high, depending on the test system
CLIA specialty
Syphilis serology (CLIA diagnostic immunology)
Common CPT codes
86592, 86593, 86780

How it works

  1. Traditional algorithm: RPR first; reactive results are confirmed with a treponemal test.
  2. Reverse sequence algorithm: Automated treponemal EIA/CIA first; reactive results reflex to a quantitative RPR, and if RPR is nonreactive, a second, different treponemal test (TP-PA) resolves the discordance.
  3. Titers: RPR titers (1:2, 1:4, 1:8 ...) are followed over time; a fourfold drop after treatment shows response.

Reading syphilis results

TreponemalRPRLikely meaning
ReactiveReactiveCurrent or recent syphilis (or previously treated with persistent titer)
ReactiveNonreactive, TP-PA reactivePast treated syphilis, or early or late untreated syphilis
ReactiveNonreactive, TP-PA nonreactiveLikely false-positive treponemal screen
NonreactiveNot doneNo serologic evidence (very early infection can be missed)

Specimen collection

Accuracy, results and interpretation

Methods, platforms and CLIA complexity

ApproachExamplesTypical CLIA category
Automated treponemal immunoassaysBio-Rad BioPlex, DiaSorin LIAISON, Abbott Architect/Alinity Syphilis TPModerate to high
RPR card testManual and automated RPRModerate
Rapid treponemal testsSyphilis Health Check (waived), DPP HIV-Syphilis, First To Know at-home test (authorized 2024)Waived

CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.

Billing codes

CodeDescription (summarized)
86592Syphilis test, nontreponemal antibody; qualitative (eg, VDRL, RPR)
86593Nontreponemal antibody; quantitative
86780Antibody; Treponema pallidum

CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.

Offering this test in your lab

CLIA requirements checklist

RequirementWhat CLIA requires
CLIA certificateA Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the syphilis serology specialty to your certificate before reporting results.
PersonnelHigh complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423).
Before patient testingVerify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253).
Quality controlControl procedures for every run under 42 CFR 493.1256.
Proficiency testingEnroll in an approved program for regulated analytes (42 CFR 493.923). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)).
CompetencyAssess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451).
RecordsKeep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105).

For specialty-level requirements and common survey findings, see Syphilis serology lab consulting.

How Sound Lab Consultants helps labs offering Syphilis test

BuildTest menu and complexity, CMS-116 and state licensure, space and workflow, instruments, SOPs, QC and PT enrollment. OverseeLaboratory director, technical consultant and technical supervisor coverage with documented oversight. ValidateMethod verification for FDA-cleared tests and full validation for modified tests and LDTs. RemediateMock inspections, plans of correction, PT failures and cease-testing responses.

Bringing Syphilis test in-house?

Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.

Book a free consultationAll lab test guides

Or call (602) 874-1311 · info@soundlabconsult.com

Frequently asked questions

Will a syphilis test always be positive after I have had syphilis?

The treponemal antibody test usually stays positive for life. The RPR titer typically declines after successful treatment and may become nonreactive.

Related lab test guides

HIV test (4th generation antigen/antibody)Most HIV testing in the US starts with a 4th-generation laboratory test that detects both HIV antibodies and the HIV-1 p24 antigen in blood, which sho.STI PCR panelAn STI PCR panel uses nucleic acid amplification to test one urine or swab specimen for several sexually transmitted infections at once, most commonly.Chlamydia and gonorrhea NAAT (CT/NG test)A nucleic acid amplification test (NAAT) is the preferred laboratory test for Chlamydia trachomatis and Neisseria gonorrhoeae.

Sources

Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.