HIV Test
Most HIV testing in the US starts with a 4th-generation laboratory test that detects both HIV antibodies and the HIV-1 p24 antigen in blood, which shortens the window period to about 18 to 45 days after exposure. A reactive result is followed by an HIV-1/HIV-2 antibody differentiation test, and by an HIV RNA test (NAT) if that is negative or indeterminate.
- Specimen
- Serum or plasma for laboratory tests; fingerstick or oral fluid for rapid and self-tests.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- General immunology (CLIA diagnostic immunology)
- Common CPT codes
- 87389, 87806, 86701 / 86702
How it works
- Screen: HIV-1/2 antigen/antibody combination immunoassay on serum or plasma.
- Differentiate: Reactive screens go to an HIV-1/HIV-2 antibody differentiation immunoassay.
- Resolve: Discordant results go to an HIV-1 NAT, which also detects acute infection.
Window periods by test type (CDC)
| Test | Approximate window period |
|---|---|
| Nucleic acid test (NAT) | 10 to 33 days |
| Lab antigen/antibody (venous blood) | 18 to 45 days |
| Rapid antigen/antibody (fingerstick) | 18 to 90 days |
| Antibody-only tests (including oral self-tests) | 23 to 90 days |
Specimen collection
- Serum or plasma for laboratory tests; fingerstick or oral fluid for rapid and self-tests.
Accuracy, results and interpretation
- A reactive rapid test is preliminary and needs laboratory confirmation.
- HIV results are reportable to the health department.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Automated 4th-gen immunoassays | Abbott Architect/Alinity HIV Ag/Ab Combo, Roche Elecsys HIV Duo, Siemens Atellica | Moderate to high |
| Supplemental differentiation | Bio-Rad Geenius HIV 1/2 | Moderate |
| Rapid | Determine HIV-1/2 Ag/Ab Combo, OraQuick ADVANCE, INSTI | Waived |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87389 | HIV-1 antigen(s) with HIV-1 and HIV-2 antibodies, single result |
| 87806 | HIV-1 antigen(s) with HIV-1 and HIV-2 antibodies, immunochromatographic (rapid) |
| 86701 / 86702 | Antibody, HIV-1 / HIV-2 (supplemental testing) |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Build reflex testing so a reactive screen moves to differentiation and NAT on the same specimen.
- Waived rapid HIV tests require counseling and confirmatory testing pathways even though the test itself is simple.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the general immunology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.927). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see General immunology lab consulting.
How Sound Lab Consultants helps labs offering HIV test
Bringing HIV test in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How soon can an HIV test detect infection?
A lab 4th-generation test can usually detect HIV 18 to 45 days after exposure; a NAT can detect it 10 to 33 days after exposure.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.