Trichomonas Test
Trichomoniasis is diagnosed by detecting Trichomonas vaginalis in a vaginal, urine or urethral specimen. A nucleic acid amplification test (NAAT) is the most sensitive method and is recommended by CDC; wet mount microscopy is fast and cheap but misses many infections.
- Specimen
- Vaginal swab (clinician- or self-collected), endocervical swab or urine in women.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- Parasitology (CLIA microbiology subspecialty)
- Common CPT codes
- 87661, 87808, 87210
How it works
- NAAT: Detects T. vaginalis RNA or DNA, often from the same specimen as chlamydia and gonorrhea testing.
- Wet mount: Vaginal fluid is examined under a microscope for motile trichomonads within minutes of collection.
- Rapid antigen: A point-of-care immunochromatographic test detects trichomonas antigen in about 10 minutes.
Trichomonas test methods compared
| Method | Sensitivity | CLIA category |
|---|---|---|
| NAAT (TMA or PCR) | Highest; recommended by CDC | Moderate to high (some waived POC) |
| Rapid antigen (OSOM) | Moderate to good | Waived |
| Wet mount microscopy | Lowest (often reported around 50% to 65%) | Provider-performed microscopy (PPM) |
| Culture | Moderate; rarely used now | Moderate/high |
Specimen collection
- Vaginal swab (clinician- or self-collected), endocervical swab or urine in women.
- Urine or urethral swab in men (NAAT).
Accuracy, results and interpretation
- CDC recommends retesting women about 3 months after treatment because reinfection is common.
- Trichomonas is a parasite, so it falls under the CLIA parasitology subspecialty.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| TMA | Aptima Trichomonas vaginalis (Panther) | High |
| PCR | cobas TV/MG, BD MAX, Xpert TV | Moderate to high |
| Rapid antigen | OSOM Trichomonas | Waived |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87661 | Trichomonas vaginalis, amplified probe |
| 87808 | Trichomonas vaginalis antigen, immunochromatographic (waived) |
| 87210 | Wet mount for infectious agents |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Wet mounts need a PPM certificate and a qualified provider reading them during the visit; a NAAT needs moderate or high complexity certification.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the parasitology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1264. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.917). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Parasitology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Trichomonas test
Bringing Trichomonas test in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
What is the most accurate test for trichomoniasis?
A NAAT. It detects far more infections than a wet mount and is CDC's recommended test.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.