Respiratory Viral Panel (RVP) PCR
A respiratory viral panel (RVP) is a multiplex molecular test that uses PCR to detect and identify the genetic material (RNA or DNA) of many respiratory viruses, and often some bacteria, at the same time from a single nasopharyngeal swab. Large panels test for 20 or more targets in about an hour.
- Specimen
- Nasopharyngeal swab in transport medium is the standard specimen for comprehensive panels.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- Virology (CLIA microbiology subspecialty)
- Common CPT codes
- 87631, 87632, 87633
How it works
- Collection: A nasopharyngeal (NP) swab is placed in viral or universal transport medium. Some smaller panels accept anterior nasal swabs.
- Extraction and reverse transcription: Nucleic acid is extracted and RNA viruses are reverse transcribed to cDNA, usually inside a sealed pouch or cartridge.
- Multiplex amplification: Many primer sets amplify all targets at once; nested or array-based designs separate them.
- Detection and report: Each target is reported as detected or not detected, with internal and process controls checked automatically.
What a respiratory panel detects
- Influenza A (with subtypes H1-2009 and H3 on many panels) and influenza B
- SARS-CoV-2 (COVID-19)
- Respiratory syncytial virus (RSV)
- Human rhinovirus / enterovirus
- Adenovirus
- Human metapneumovirus (hMPV)
- Parainfluenza viruses 1 to 4
- Seasonal coronaviruses 229E, HKU1, NL63 and OC43
- On comprehensive panels: Bordetella pertussis and parapertussis, Mycoplasma pneumoniae and Chlamydia pneumoniae
Specimen collection
- Nasopharyngeal swab in transport medium is the standard specimen for comprehensive panels.
- Lower respiratory panels use bronchoalveolar lavage (BAL) or sputum and add bacterial targets and resistance genes.
- Calcium alginate or cotton swabs and wooden shafts can inhibit PCR; follow the package insert.
Accuracy, results and interpretation
- Detecting a virus's nucleic acid does not always mean it is causing the current illness: rhinovirus and adenovirus can be shed for weeks.
- Co-detections are common in children.
- A negative panel does not rule out infection with an organism the panel doesn't include.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Comprehensive syndromic panels (about 20+ targets) | BioFire RP2.1, QIAstat-Dx Respiratory SARS-CoV-2 Panel, ePlex RP2, NxTAG RPP | Moderate (some high) |
| Targeted 4-plex | Xpert Xpress CoV-2/Flu/RSV plus, cobas SARS-CoV-2 & Influenza A/B, Alinity m Resp-4-Plex | Waived to high |
| Waived mini panels | BioFire Spotfire R/ST, cobas liat | Waived |
| Laboratory-developed RVP | Open qPCR with lab-designed primers | High (LDT) |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87631 | Respiratory virus, multiplex amplified probe, 3-5 targets |
| 87632 | Same, 6-11 targets |
| 87633 | Same, 12-25 targets |
| 87637 | SARS-CoV-2, influenza A and B, and RSV, multiplex amplified probe |
| 0202U | BioFire Respiratory Panel 2.1 (22 targets) |
| 0115U / 0223U | Other proprietary respiratory panels (ePlex RP, QIAstat-Dx) |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Payers increasingly limit large panels: many policies cover up to 5 targets in the outpatient setting and reserve larger panels for immunocompromised or hospitalized patients, and Medicare MolDX has a dedicated LCD for syndromic panels (L39044). Build your test menu around medical necessity, not panel size.
- Decide on sample-to-answer (fast, simple staffing, higher cost per test) versus batch PCR (cheaper per test, high complexity staffing and workflow).
- Plan seasonal capacity: respiratory volume can triple between summer and the winter peak.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the virology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1265. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.919). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Virology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Respiratory viral panel
Bringing Respiratory viral panel in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How long does a respiratory viral panel take?
Sample-to-answer panels give results in about 45 to 75 minutes on the instrument. Sent-out panels typically return in 1 to 3 days including transport.
What is the difference between an RVP and a COVID test?
A COVID test looks only for SARS-CoV-2. An RVP looks for many respiratory viruses (and sometimes bacteria) at once, including SARS-CoV-2 on current panels.
Is a respiratory viral panel covered by insurance?
Coverage depends on the payer and the number of targets. Many payers cover small panels (5 or fewer targets) for outpatients and require specific clinical criteria for larger panels.
Can an urgent care run a respiratory panel in-house?
Yes. Some panels are CLIA-waived; others are moderate complexity and need a Certificate of Compliance or Accreditation, a technical consultant and method verification.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.
