Nucleic Acid Amplification Test (NAAT)
A nucleic acid amplification test (NAAT) is a laboratory method that makes millions of copies of a specific DNA or RNA sequence so that very small amounts of an organism's genetic material can be detected. Because it looks for the pathogen's genes rather than antibodies or proteins, a NAAT can find infections earlier and in smaller samples than culture or antigen tests.
- Specimen
- Swabs (nasopharyngeal, nasal, throat, vaginal, endocervical, rectal, lesion) in the transport medium the assay is cleared for.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- Molecular diagnostics
- Common CPT codes
- 87xxx series, 87631-87633, 87798 / 87801
How it works
- Sample preparation: The specimen (swab, urine, blood, plasma or tissue) is lysed to break open cells and viral particles, and the DNA or RNA is extracted and purified. Many modern systems do this automatically inside a closed cartridge.
- Amplification: Enzymes copy the target sequence over and over. PCR uses repeated heating and cooling cycles; isothermal methods such as TMA, LAMP and NEAR copy the target at one constant temperature. RNA targets are first converted to DNA by reverse transcription (RT).
- Detection: Fluorescent probes, dyes or other reporters signal when the target is present. Real-time methods read the signal during amplification, which also allows the amount of target to be measured (a viral load).
- Controls and result: An internal control checks that extraction and amplification worked in each sample, and positive and negative controls check each run. The result is reported as detected or not detected, or as a quantity.
Common NAAT methods
| Method | How it amplifies | Common uses |
|---|---|---|
| PCR and real-time PCR (qPCR) | Thermal cycling with a DNA polymerase | Respiratory panels, STIs, HPV, MRSA, GI panels, genetics |
| RT-PCR | Reverse transcription of RNA, then PCR | SARS-CoV-2, influenza, HIV and HCV viral loads |
| Transcription-mediated amplification (TMA) | Isothermal, RNA polymerase and reverse transcriptase | Chlamydia, gonorrhea, trichomonas, Mycoplasma genitalium, HPV mRNA |
| Strand displacement amplification (SDA) | Isothermal strand displacement | CT/NG on some automated platforms |
| Loop-mediated isothermal amplification (LAMP) | Isothermal, 4 to 6 primers | Rapid and point-of-care infectious disease tests |
| Nicking enzyme amplification reaction (NEAR) | Isothermal, nicking enzyme and polymerase | Rapid influenza, strep A and COVID-19 instruments |
| Helicase-dependent amplification (HDA) | Isothermal, helicase unwinds DNA | Some rapid C. difficile and HSV assays |
Specimen collection
- Swabs (nasopharyngeal, nasal, throat, vaginal, endocervical, rectal, lesion) in the transport medium the assay is cleared for.
- First-catch urine for many STI assays.
- Plasma or serum for viral loads (HIV, HCV, HBV, CMV).
- Stool, cerebrospinal fluid, positive blood culture broth, sputum and tissue for specific assays.
- Using a collection device or specimen type the assay was not cleared for turns the test into a modified test that the lab must fully validate.
Accuracy, results and interpretation
- NAATs are the most sensitive routine method for most infections, which is why CDC recommends them as the preferred test for chlamydia and gonorrhea.
- Because they detect nucleic acid, not live organisms, NAATs can stay positive after successful treatment while residual DNA or RNA clears.
- False positives most often come from contamination by amplified product; false negatives from inhibition, poor collection or targets below the limit of detection.
- Quantitative NAATs report copies/mL or IU/mL and are used to monitor treatment (viral loads).
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Sample-to-answer cartridge PCR | Cepheid GeneXpert, BioFire FilmArray/Spotfire, QIAstat-Dx, cobas liat | Waived to moderate |
| Automated high-throughput NAAT | Hologic Panther, Roche cobas 5800/6800/8800, Abbott Alinity m, BD COR/BD MAX | Moderate to high |
| Open real-time PCR (LDT) | Thermo QuantStudio, Bio-Rad CFX with lab-developed primers and probes | High (LDT) |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87xxx series | Infectious agent detection by nucleic acid: separate codes per organism and for direct probe, amplified probe and quantification |
| 87631-87633 | Respiratory virus multiplex panels by number of targets |
| 87798 / 87801 | Amplified probe for an organism without its own code / multiple organisms |
| PLA (U) codes | Proprietary panels such as BioFire RP2.1 (0202U) |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Choose between closed cartridge systems (simpler facility needs, lower complexity) and open or batch systems (lower cost per test, high complexity, unidirectional workflow).
- Decide whether every test you plan is FDA-cleared as used, or whether any is modified or lab-developed and needs a full validation.
- Plan the room layout and air handling for contamination control before you sign a lease.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the molecular diagnostics specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)). |
| Proficiency testing | Where no approved proficiency testing exists for a test, verify its accuracy at least twice a year, for example by split-sample comparison or an available external survey (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Molecular diagnostics lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering NAAT testing
Bringing NAAT testing in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Is a NAAT the same as a PCR test?
PCR is one type of NAAT. NAAT is the umbrella term that also includes isothermal methods such as TMA, LAMP, SDA and NEAR. All of them amplify a target DNA or RNA sequence.
How accurate is a NAAT?
NAATs are highly sensitive and specific when the specimen is collected correctly and the assay is used as cleared. For most infections they detect far smaller amounts of organism than antigen tests or culture.
Why can a NAAT be positive after treatment?
A NAAT detects genetic material, which can remain for days to weeks after the organism is killed. For chlamydia and gonorrhea, CDC advises against test-of-cure NAATs sooner than about four weeks after treatment.
Can a clinic run NAATs in-house?
Yes. Some cartridge NAATs are CLIA-waived and can run under a Certificate of Waiver; most lab-based NAATs are moderate or high complexity and need a Certificate of Compliance or Accreditation, qualified personnel and method verification.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.
