Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultants › Lab test guides › Strep A test (rapid antigen vs PCR)

Strep Test

Reviewed November 28, 2026 by the Sound Lab Consultants laboratory team · Bacteriology (CLIA microbiology subspecialty)

Short answer

Strep throat is diagnosed by testing a throat swab for group A Streptococcus (Streptococcus pyogenes). A rapid antigen test gives results in about 10 minutes but can miss infections, so negative rapid tests in children and teens should be confirmed with a throat culture. Molecular (NAAT) strep tests are about as sensitive as culture and generally do not need a backup culture.

Specimen
Throat swab; follow the test's swab type and transport requirements.
CLIA complexity
Waived
CLIA specialty
Bacteriology (CLIA microbiology subspecialty)
Common CPT codes
87880, 87651, 87081

How it works

  1. Throat swab: Both tonsils (or tonsillar fossae) and the posterior pharynx are swabbed, avoiding the tongue.
  2. Test: Rapid antigen, molecular NAAT, or culture on blood agar.

Strep A test options

TestTimeNotes
Rapid antigen (RADT)About 5 to 10 minutesWaived; negative results in children need culture backup per IDSA
Molecular NAATAbout 2 to 15 minutes on POC systemsWaived options available; high sensitivity
Throat culture24 to 48 hoursReference method; needs moderate/high complexity certification

Specimen collection

Accuracy, results and interpretation

Methods, platforms and CLIA complexity

ApproachExamplesTypical CLIA category
Molecular POCAbbott ID NOW Strep A 2, cobas liat Strep A, Xpert Xpress Strep AWaived
Rapid antigenMany lateral-flow kitsWaived

CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.

Billing codes

CodeDescription (summarized)
87880Streptococcus group A antigen, immunoassay with direct optical observation
87651Streptococcus group A, amplified probe
87081Culture, presumptive pathogenic organisms, screening only

CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.

Offering this test in your lab

CLIA requirements checklist

RequirementWhat CLIA requires
CLIA certificateA Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results.
PersonnelHigh complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423).
Before patient testingVerify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253).
Quality controlControl procedures for every run under 42 CFR 493.1256, plus the specialty rules in 42 CFR 493.1261.
Proficiency testingEnroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)).
CompetencyAssess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451).
RecordsKeep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105).

For specialty-level requirements and common survey findings, see Bacteriology lab consulting.

How Sound Lab Consultants helps labs offering Strep A test

BuildTest menu and complexity, CMS-116 and state licensure, space and workflow, instruments, SOPs, QC and PT enrollment. OverseeLaboratory director, technical consultant and technical supervisor coverage with documented oversight. ValidateMethod verification for FDA-cleared tests and full validation for modified tests and LDTs. RemediateMock inspections, plans of correction, PT failures and cease-testing responses.

Bringing Strep A test in-house?

Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.

Book a free consultationAll lab test guides

Or call (602) 874-1311 · info@soundlabconsult.com

Frequently asked questions

Is a rapid strep test accurate?

It is very specific, so a positive is reliable. Sensitivity is lower, which is why negative results in children and adolescents should be confirmed with culture, unless a molecular test was used.

Related lab test guides

COVID, flu and RSV PCR test (4-plex)A COVID, flu and RSV PCR test is a multiplex molecular test that detects and tells apart SARS-CoV-2, influenza A, influenza B and respiratory syncytia.Respiratory viral panel (RVP)A respiratory viral panel (RVP) is a multiplex molecular test that uses PCR to detect and identify the genetic material (RNA or DNA) of many respirato.Nucleic acid amplification test (NAAT)A nucleic acid amplification test (NAAT) is a laboratory method that makes millions of copies of a specific DNA or RNA sequence so that very small amo.

Sources

Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.