COVID, Flu & RSV PCR Test (4-Plex)
A COVID, flu and RSV PCR test is a multiplex molecular test that detects and tells apart SARS-CoV-2, influenza A, influenza B and respiratory syncytial virus (RSV) from one nasal or nasopharyngeal swab. It is billed with CPT 87637 and runs on platforms ranging from CLIA-waived point-of-care analyzers to high-throughput lab systems.
- Specimen
- Anterior nasal or NP swab in the specified medium; some point-of-care systems need the swab tested directly or within a set time.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- Virology (CLIA microbiology subspecialty)
- Common CPT codes
- 87637, 87636, 87635
How it works
- Swab: Anterior nasal or nasopharyngeal swab, depending on the assay.
- RT-PCR: Viral RNA is reverse transcribed and the four targets are amplified together with an internal control.
- Result: Each virus is reported as detected or not detected in about 20 minutes on point-of-care systems.
Why the 4-plex replaced single tests
- Symptoms of COVID-19, influenza and RSV overlap, so one swab answers all three.
- Antivirals differ: oseltamivir or baloxavir for flu, nirmatrelvir/ritonavir or remdesivir for COVID-19.
- Infection control and cohorting decisions in hospitals depend on which virus is present.
- One code (87637) replaced billing three separate tests.
Specimen collection
- Anterior nasal or NP swab in the specified medium; some point-of-care systems need the swab tested directly or within a set time.
Accuracy, results and interpretation
- Molecular 4-plex tests are more sensitive than rapid antigen tests, especially early or late in illness.
- Positive results for SARS-CoV-2 can persist after recovery.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Point-of-care | cobas liat SARS-CoV-2 & Influenza A/B (+RSV on newer panels), Xpert Xpress CoV-2/Flu/RSV plus (GeneXpert Xpress), ID NOW (flu and COVID separately) | Waived (check the exact system) |
| Lab analyzers | Xpert on GeneXpert Dx/Infinity, Alinity m Resp-4-Plex, cobas 6800/8800, Panther Fusion | Moderate to high |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87637 | SARS-CoV-2, influenza A and B, and RSV, multiplex amplified probe |
| 87636 | SARS-CoV-2 and influenza A and B, multiplex amplified probe |
| 87635 | SARS-CoV-2, amplified probe |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Waived 4-plex platforms let urgent cares and physician offices test under a Certificate of Waiver, provided they follow the manufacturer's instructions exactly.
- The same cartridge on a non-waived instrument configuration can be moderate complexity; complexity follows the test system, not just the cartridge.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the virology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1265. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.919). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Virology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering COVID, flu and RSV PCR test
Bringing COVID, flu and RSV PCR test in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Is the COVID/flu/RSV test a PCR test?
Most combined COVID/flu/RSV tests are RT-PCR or another NAAT. Rapid antigen combination tests also exist but are less sensitive.
Can a clinic with a CLIA waiver run a COVID/flu/RSV PCR?
Yes, if the specific test system is categorized as waived. Check the FDA CLIA database for the exact instrument and cartridge.