Hepatitis C RNA Test (HCV PCR)
A hepatitis C RNA test (HCV PCR or HCV NAAT) detects and usually measures the genetic material of the hepatitis C virus in blood. Because an HCV antibody test stays positive after the infection is cured, a positive antibody must be followed by an HCV RNA test to confirm current infection. HCV RNA is also used to confirm cure 12 weeks after treatment.
- Specimen
- Serum or EDTA plasma separated within the assay's time limit.
- CLIA complexity
- Waived to high, depending on the test system
- CLIA specialty
- Virology (CLIA microbiology subspecialty)
- Common CPT codes
- 87522, 87521, 87902
How it works
- Antibody first: CDC's testing sequence starts with an HCV antibody test; reactive results reflex to HCV RNA.
- RNA detection: HCV RNA is extracted from serum or plasma and measured by quantitative RT-PCR or TMA.
- Result: Detected with a viral load in IU/mL, detected below quantification, or not detected.
HCV antibody and RNA results together
| Antibody | HCV RNA | Interpretation |
|---|---|---|
| Nonreactive | Not tested | No HCV antibody detected |
| Reactive | Detected | Current HCV infection |
| Reactive | Not detected | Past, resolved infection (or false-positive antibody) |
Specimen collection
- Serum or EDTA plasma separated within the assay's time limit.
- Point-of-care HCV RNA testing on fingerstick blood is now available (Xpert HCV, CLIA-waived since 2024), enabling test-and-treat in one visit.
Accuracy, results and interpretation
- Sustained virologic response (SVR12), meaning undetectable RNA 12 weeks after therapy, is considered a cure.
- HCV genotyping is less often required with pan-genotypic regimens.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Automated quantitative NAAT | Roche cobas HCV, Abbott Alinity m HCV, Hologic Aptima HCV Quant Dx | High (some moderate) |
| Point-of-care HCV RNA | Cepheid Xpert HCV (fingerstick) | Waived |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87522 | HCV, quantification |
| 87521 | HCV, amplified probe (qualitative) |
| 87902 | HCV genotype |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Set up reflex ordering from antibody to RNA on the same draw so patients don't need a second visit.
- Waived point-of-care HCV RNA testing still requires the lab to follow the manufacturer's instructions and keep training records.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the virology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1265. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.919). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Virology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Hepatitis C RNA
Bringing Hepatitis C RNA in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Why do I need an HCV RNA test after a positive antibody?
Antibodies remain after an infection clears or is cured. Only an RNA test shows whether the virus is still present.
Is there a rapid HCV RNA test?
Yes. FDA authorized a CLIA-waived fingerstick HCV RNA test (Cepheid Xpert HCV) in 2024 that gives results in about an hour.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.