Bacterial Vaginosis Test & Vaginitis PCR Panel
Bacterial vaginosis (BV) is diagnosed clinically with Amsel criteria, by a Gram stain scored with the Nugent method, or with an FDA-cleared molecular vaginitis panel that measures BV-associated bacteria and Lactobacillus and, on many panels, also detects Candida species and Trichomonas vaginalis from one vaginal swab.
- Specimen
- Vaginal swab collected with the panel's kit (clinician- or self-collected, per labeling).
- CLIA complexity
- PPM to high, depending on the test system
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 81513, 81514, 87210
How it works
- Amsel criteria: Three of four: thin homogeneous discharge, clue cells on wet mount, vaginal pH above 4.5, and a fishy odor with KOH (whiff test).
- Nugent score: A Gram stain of vaginal fluid is scored 0 to 10 by counts of Lactobacillus, Gardnerella/Bacteroides and Mobiluncus morphotypes; 7 to 10 is BV.
- Molecular panel: Quantitative PCR or TMA measures BV markers (Gardnerella, Atopobium/Fannyhessea, BVAB-2, Megasphaera, Lactobacillus) and reports an algorithm result.
What a vaginitis panel covers
- Bacterial vaginosis (algorithm positive or negative)
- Candida species (C. albicans group) and often C. glabrata and C. krusei reported separately
- Trichomonas vaginalis
Specimen collection
- Vaginal swab collected with the panel's kit (clinician- or self-collected, per labeling).
Accuracy, results and interpretation
- Molecular panels avoid the subjectivity of wet mount reading and can detect mixed infections.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Molecular vaginitis panels | BD MAX Vaginal Panel, Aptima BV and Aptima CV/TV (Panther) | High |
| Microscopy | Wet mount and KOH under PPM | PPM |
| Gram stain Nugent score | Read by laboratory staff | High |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 81513 | BV, quantitative real-time amplification of RNA markers (algorithm) |
| 81514 | BV and vaginitis panel with separate detection of Candida species and Trichomonas vaginalis |
| 87210 | Wet mount |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- OB/GYN groups often move from PPM wet mounts to a molecular vaginitis panel once volume justifies a moderate/high complexity lab.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Bacterial vaginosis and vaginitis panel
Bringing Bacterial vaginosis and vaginitis panel in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
What is the gold standard test for bacterial vaginosis?
The Nugent-scored Gram stain is the research gold standard; Amsel criteria are used clinically, and FDA-cleared molecular panels perform comparably with less subjectivity.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.