Reviewed November 28, 2026 by the Sound Lab Consultants laboratory team · Bacteriology (CLIA microbiology subspecialty)

Short answer

A MRSA PCR nasal screen detects the DNA of methicillin-resistant Staphylococcus aureus (MRSA), usually by targeting the mecA/mecC gene and its junction with the S. aureus chromosome, from a swab of the front of the nose. Results in about an hour guide isolation, pre-surgery decolonization and, because a negative result is highly predictive, stopping empiric MRSA antibiotics in pneumonia.

Specimen
Anterior nares swab in the assay's transport system.
CLIA complexity
Moderate to high, depending on the test system
CLIA specialty
Bacteriology (CLIA microbiology subspecialty)
Common CPT codes
87641, 87640

How it works

  1. Swab: Both anterior nares are swabbed with one swab.
  2. PCR: MRSA-specific targets (and S. aureus on combined assays) are amplified.
  3. Result: MRSA positive or negative, and S. aureus (MSSA) positive or negative on combined assays.

How MRSA screens are used

Specimen collection

Accuracy, results and interpretation

Methods, platforms and CLIA complexity

ApproachExamplesTypical CLIA category
Cartridge PCRXpert MRSA NxG, Xpert SA Nasal CompleteModerate
Batch PCRBD MAX MRSA XT, cobas MRSA/SAModerate to high

CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.

Billing codes

CodeDescription (summarized)
87641Staphylococcus aureus, methicillin resistant, amplified probe
87640Staphylococcus aureus, amplified probe

CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.

Offering this test in your lab

CLIA requirements checklist

RequirementWhat CLIA requires
CLIA certificateA Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results.
PersonnelHigh complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423).
Facility and workflowAmplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)).
Before patient testingVerify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253).
Quality controlControl procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261.
Proficiency testingEnroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)).
CompetencyAssess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451).
RecordsKeep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105).

For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.

How Sound Lab Consultants helps labs offering MRSA PCR nasal screen

BuildTest menu and complexity, CMS-116 and state licensure, space and workflow, instruments, SOPs, QC and PT enrollment. OverseeLaboratory director, technical consultant and technical supervisor coverage with documented oversight. ValidateMethod verification for FDA-cleared tests and full validation for modified tests and LDTs. RemediateMock inspections, plans of correction, PT failures and cease-testing responses.

Bringing MRSA PCR nasal screen in-house?

Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.

Book a free consultationAll lab test guides

Or call (602) 874-1311 · info@soundlabconsult.com

Frequently asked questions

How long does a MRSA PCR take?

About 1 hour on cartridge systems, compared with 24 to 48 hours for chromogenic culture.

Related lab test guides

Antimicrobial susceptibility testing (AST)Antimicrobial susceptibility testing (AST) measures how well antibiotics inhibit a bacterial isolate, usually as a minimum inhibitory concentration (M.Blood cultureA blood culture places a patient's blood into bottles of growth medium that an automated system monitors for growth of bacteria or yeast.Real-time PCR (qPCR) testA real-time PCR (qPCR) test copies a target DNA sequence through repeated heating and cooling cycles and measures the fluorescent signal after every c.