MRSA PCR Nasal Screen
A MRSA PCR nasal screen detects the DNA of methicillin-resistant Staphylococcus aureus (MRSA), usually by targeting the mecA/mecC gene and its junction with the S. aureus chromosome, from a swab of the front of the nose. Results in about an hour guide isolation, pre-surgery decolonization and, because a negative result is highly predictive, stopping empiric MRSA antibiotics in pneumonia.
- Specimen
- Anterior nares swab in the assay's transport system.
- CLIA complexity
- Moderate to high, depending on the test system
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87641, 87640
How it works
- Swab: Both anterior nares are swabbed with one swab.
- PCR: MRSA-specific targets (and S. aureus on combined assays) are amplified.
- Result: MRSA positive or negative, and S. aureus (MSSA) positive or negative on combined assays.
How MRSA screens are used
- Infection control: contact precautions on admission.
- Pre-operative screening before cardiac and orthopedic surgery, followed by decolonization.
- Antimicrobial stewardship: a negative nasal MRSA PCR has a very high negative predictive value for MRSA pneumonia, supporting vancomycin de-escalation.
Specimen collection
- Anterior nares swab in the assay's transport system.
Accuracy, results and interpretation
- Rare mecA variants or SCCmec types can cause false negatives on some assays; confirm by culture when clinically suspected.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Cartridge PCR | Xpert MRSA NxG, Xpert SA Nasal Complete | Moderate |
| Batch PCR | BD MAX MRSA XT, cobas MRSA/SA | Moderate to high |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87641 | Staphylococcus aureus, methicillin resistant, amplified probe |
| 87640 | Staphylococcus aureus, amplified probe |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- MRSA screening volumes are predictable (admissions, surgery schedule); size reagent orders and staffing to the surgical calendar.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering MRSA PCR nasal screen
Bringing MRSA PCR nasal screen in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How long does a MRSA PCR take?
About 1 hour on cartridge systems, compared with 24 to 48 hours for chromogenic culture.
Related lab test guides