Antimicrobial Susceptibility Testing (AST)
Antimicrobial susceptibility testing (AST) measures how well antibiotics inhibit a bacterial isolate, usually as a minimum inhibitory concentration (MIC) or a disk diffusion zone size. The result is interpreted against breakpoints as susceptible (S), susceptible-dose dependent (SDD), intermediate (I) or resistant (R) to guide treatment.
- Specimen
- Pure bacterial isolates from culture.
- CLIA complexity
- High complexity
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87186, 87184, 87181
How it works
- Pure isolate: A standardized inoculum (0.5 McFarland) is prepared from a pure culture.
- Test method: Broth microdilution, automated panels, gradient strips or disk diffusion on Mueller-Hinton agar.
- Incubation: Usually 16 to 20 hours (rapid systems are faster).
- Interpretation: MICs or zone diameters are compared with current CLSI or FDA breakpoints.
AST methods
| Method | Output | Examples |
|---|---|---|
| Broth microdilution (reference) | MIC | Frozen or dried panels |
| Automated AST | MIC | VITEK 2, BD Phoenix, MicroScan WalkAway |
| Gradient diffusion | MIC | Etest, MTS strips |
| Disk diffusion | Zone diameter | Kirby-Bauer |
| Rapid phenotypic | MIC from positive blood culture | Accelerate Pheno |
Specimen collection
- Pure bacterial isolates from culture.
Accuracy, results and interpretation
- CLSI updates breakpoints yearly (M100); FDA recognizes CLSI breakpoints, and labs must update their systems or document limitations when breakpoints change.
- Cascade or selective reporting supports antimicrobial stewardship.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Automated systems | VITEK 2, Phoenix, MicroScan | High |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87186 | Susceptibility, microdilution or agar dilution (MIC), each multi-antimicrobial plate |
| 87184 | Disk diffusion, per plate |
| 87181 | Agar dilution or gradient, per agent |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- CLIA requires each batch or lot and shipment of AST media and agents to be checked with control organisms before use, and controls each day tests are run unless the lab qualifies for weekly QC (42 CFR 493.1261(b)).
- Using breakpoints older than current FDA-recognized ones is a frequent survey finding.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting.
How Sound Lab Consultants helps labs offering Antimicrobial susceptibility testing
Bringing Antimicrobial susceptibility testing in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
What does SDD mean on a susceptibility report?
Susceptible-dose dependent: the isolate can be treated if a higher dose or more frequent dosing is used.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.