Blood Culture Test
A blood culture places a patient's blood into bottles of growth medium that an automated system monitors for growth of bacteria or yeast. It is the main test for bloodstream infection and sepsis: when a bottle flags positive, the lab performs a Gram stain, rapid identification (often a molecular panel or MALDI-TOF) and susceptibility testing.
- Specimen
- Blood inoculated directly into bottles at the bedside; transport to the lab without refrigeration.
- CLIA complexity
- Moderate to high, depending on the test system
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87040, 87205, 87154
How it works
- Collection: Two to four sets (each an aerobic and an anaerobic bottle) are drawn from separate venipunctures with skin antisepsis; adults typically need 20 mL per set.
- Incubation: Bottles are incubated in a continuous-monitoring system (BD BACTEC, bioMérieux BacT/ALERT) for 5 days.
- Positive bottle: Gram stain is called to the clinician as a critical value; rapid ID panels or MALDI-TOF follow.
- AST: Susceptibility testing on the isolate, or rapid phenotypic AST directly from the bottle on some systems.
Quality measures labs track
- Contamination rate: CLSI recommends 3% or less, and many programs now target 1%.
- Blood volume per bottle (underfilling is the main cause of false negatives).
- Single-set rate (single sets make contaminants hard to interpret).
- Time from positive to Gram stain call and to rapid ID.
Specimen collection
- Blood inoculated directly into bottles at the bedside; transport to the lab without refrigeration.
Accuracy, results and interpretation
- Coagulase-negative staphylococci in one of several sets usually represent contamination.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Continuous-monitoring systems | BD BACTEC FX, BacT/ALERT VIRTUO | High |
| Rapid ID from positive bottles | BioFire BCID2, ePlex BCID, Verigene, Accelerate Pheno (AST) | Moderate to high |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87040 | Culture, bacterial; blood, aerobic, with isolation and presumptive ID |
| 87205 | Smear, Gram stain |
| 87154 | Blood pathogen and resistance typing, multiplex amplified probe, 6 or more targets, per culture |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Small hospitals and freestanding ERs often collect and incubate blood cultures but refer positive bottles; define that handoff and the Gram stain call process in writing.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting.
How Sound Lab Consultants helps labs offering Blood culture
Bringing Blood culture in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How long do blood culture results take?
Most positives flag within 24 to 48 hours; cultures are finalized as negative after 5 days.
Related lab test guides
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.