Urine Culture & Sensitivity
A urine culture grows bacteria (or yeast) from a urine sample on agar to find out whether a urinary tract infection is present, which organism is causing it and how many colonies are present (CFU/mL). If a likely pathogen grows, susceptibility testing (the 'sensitivity') shows which antibiotics will work.
- Specimen
- Midstream clean-catch, straight catheter or suprapubic urine; never from a urine bag.
- CLIA complexity
- High complexity
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87086, 87088, 87077
How it works
- Collection: Midstream clean-catch or catheter urine, refrigerated or in a preservative tube if not plated within about 2 hours.
- Plating: A calibrated loop (1 µL or 10 µL) streaks urine onto blood and MacConkey (or chromogenic) agar.
- Incubation and count: After 18 to 24 hours, colonies are counted and converted to CFU/mL.
- ID and AST: Significant isolates are identified (MALDI-TOF or biochemical) and tested for susceptibility.
Interpreting colony counts
- Counts of 100,000 CFU/mL or more of a single uropathogen are the classic threshold for clean-catch urine.
- Lower counts can be significant in symptomatic patients, catheter specimens and men.
- Three or more organisms usually indicate contamination and a recollection.
Specimen collection
- Midstream clean-catch, straight catheter or suprapubic urine; never from a urine bag.
- Unpreserved urine must be plated within 2 hours or refrigerated (up to 24 hours).
Accuracy, results and interpretation
- Asymptomatic bacteriuria generally should not be treated except in pregnancy and before urologic procedures.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Manual plating | Calibrated loops | High (culture and ID) |
| Automated plating and reading | BD Kiestra, Copan WASP | High |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87086 | Culture, bacterial; quantitative colony count, urine |
| 87088 | With isolation and presumptive identification of each isolate, urine |
| 87077 | Aerobic isolate, additional identification methods |
| 87186 | Susceptibility, microdilution or agar dilution (MIC), each plate |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Bacterial culture puts a lab in the CLIA bacteriology subspecialty with weekly Gram stain QC, media QC and AST QC under 42 CFR 493.1261.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting.
How Sound Lab Consultants helps labs offering Urine culture and sensitivity
Bringing Urine culture and sensitivity in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
How long does a urine culture take?
Usually 24 hours for a negative and 48 to 72 hours for identification and sensitivities on a positive.
Related lab test guides
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.