Short answer: International labs reach US patients in four ways: (1) a US subsidiary that owns a new CLIA lab, (2) acquisition of an existing CLIA lab, (3) a US reference lab that validates and runs your assay under its own CLIA certificate, or (4) send-out of US specimens to your home lab after it obtains a CLIA certificate from CMS. Own or acquired labs give control and Medicare billing; reference-lab and send-out models are lighter but give up control, and Medicare generally does not pay for services furnished outside the US.
Last reviewed November 26, 2026. Primary sources: eCFR, eCFR, eCFR.
Sound Lab Consultants is an independent, advisory clinical laboratory consulting firm. This page is general information about US laboratory requirements, not legal, tax, immigration or customs advice. For entity, tax, investment-review or visa questions, work with a US attorney, a CPA and, for visas, an immigration attorney; always confirm current rules with the agency named.

Side-by-side comparison
| Own US lab (subsidiary) | Acquire a CLIA lab | US reference lab runs your assay | Send-out to your CLIA-certified home lab | |
|---|---|---|---|---|
| Control of test and data | Full | Full after closing | Shared, by contract | Full |
| Time to first US result | Longest | Shorter | Shorter | Depends on CMS certification and shipping |
| CLIA certificate | New CMS-116 | Existing; CHOW notice in 30 days | Reference lab's | Your home lab's, via CMS |
| State licenses (NY, CA, PA, MD, RI, NJ) | You obtain | Transfer or re-apply | Reference lab's | Still apply to your lab |
| Medicare billing | Yes, after enrollment | Yes, update enrollment | Reference lab bills | Generally no payment for services outside the US (42 CFR 411.9) |
| Specimen import | Not needed for US patients | Not needed | Not needed | US specimen export, return shipping, data transfer |
The US subsidiary lab
Most groups form a US entity that leases space, employs staff and holds the CLIA certificate. The parent provides capital and know-how, often under service and licensing agreements. Keep the CLIA director's authority clear: CLIA makes the director responsible for the lab's overall operation (42 CFR 493.1445). Entity questions: entity setup basics.
Placing your assay with a US reference lab
The US lab must validate the assay itself under 42 CFR 493.1253, own the SOPs, and report under its own CLIA number and state licenses. Your contract should cover tech transfer, reagent supply, change control, data and publication rights. See transferring assays to a US lab and reference laboratory consulting.
Hub and spoke
Some groups open one high complexity US hub and keep specialised or research testing at home. US patient-reportable testing at the hub follows CLIA; research-only work that never reports patient-specific results falls outside CLIA under 42 CFR 493.3(b)(2).
How to pick
- Expected US volume high and long-term: own lab or acquisition.
- Need speed and existing payer contracts: acquisition.
- Validating demand: reference lab first, own lab later.
- Rare, specialised tests with non-Medicare clients: CLIA-certify the home lab, see home-lab CLIA vs US lab.
Plan your US laboratory with us
Book a free consultation. Tell us your home country, test menu, target states and timing, and we will map the US licensing, director, validation and launch steps in order. Sound Lab Consultants is advisory: we work alongside your attorney and accountant.
Book a free consultationFrequently asked questions
Can a US reference lab run our proprietary assay?
Yes, as its own LDT. It must validate the test under 42 CFR 493.1253 and report under its CLIA certificate and state licenses.
Can our home lab bill Medicare for US patients?
Generally no. Medicare generally does not pay for services furnished outside the United States (42 CFR 411.9).
Who holds the CLIA certificate in a subsidiary model?
The US laboratory, owned by the US entity, with a qualified laboratory director named on Form CMS-116.
Is research testing in our US lab subject to CLIA?
Not if it does not report patient-specific results for diagnosis, prevention, treatment or health assessment (42 CFR 493.3(b)(2)). Reported clinical results are subject to CLIA.
Can we start with a reference lab and move to our own lab later?
Yes. Plan the contract so data, validation files and change control support a later transfer.
Does SLC help choose a model?
Yes. We compare the models against your test menu, states and timing and work alongside your legal and finance advisors.
Official sources
- eCFR, 42 CFR 493.3 Applicability
- eCFR, 42 CFR 493.1253 Establishment and verification of performance specifications
- eCFR, 42 CFR 493.1445 Laboratory director responsibilities (high complexity)
- eCFR, 42 CFR 411.9 Services furnished outside the United States
- CMS, Apply for a CLIA certificate
- CMS, Applicability of CLIA to International Laboratories (PDF)
- NYSDOH Wadsworth Center, Obtain a clinical laboratory permit (CLEP)
Related pages
Sound Lab Consultants is an independent, advisory clinical laboratory consulting firm. This page is general information about US laboratory requirements, not legal, tax, immigration or customs advice. For entity, tax, investment-review or visa questions, work with a US attorney, a CPA and, for visas, an immigration attorney; always confirm current rules with the agency named. Sound Lab Consultants is not affiliated with or endorsed by CMS, FDA, CDC, OSHA, HHS, OIG, CAP, COLA, The Joint Commission, CLSI, ISO, ILAC, any national accreditation body or foreign regulator, any state agency, or any instrument or reagent manufacturer or distributor. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.