Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
International labs · US market entry · Advisory

Transferring and validating your assays in a US lab

Your home validation is useful evidence, but the US lab's CLIA director must sign a US validation done on the US system.

Short answer: An FDA-cleared or approved test used unmodified needs verification of accuracy, precision, reportable range and reference intervals in the US lab. Anything else, including CE-IVD kits without FDA authorization, modified tests and in-house assays, is an LDT that needs full validation of accuracy, precision, analytical sensitivity, analytical specificity including interferences, reportable range, reference intervals and any other relevant characteristic, under 42 CFR 493.1253. Home-country data can inform the design and acceptance criteria, but the studies must be run on the US instrument, reagents and staff. New York also requires test approval for LDTs.

Last reviewed November 26, 2026. Primary sources: eCFR, FDA, Federal Register.

Sound Lab Consultants is an independent, advisory clinical laboratory consulting firm. This page is general information about US laboratory requirements, not legal, tax, immigration or customs advice. For entity, tax, investment-review or visa questions, work with a US attorney, a CPA and, for visas, an immigration attorney; always confirm current rules with the agency named.

Transferring and validating your assays in a US lab overview graphic from Sound Lab Consultants

Verification or validation?

Test status in the USWhat 493.1253 requires
FDA-cleared/approved, unmodifiedVerify accuracy, precision, reportable range, reference intervals
FDA test, modifiedFull validation (it becomes an LDT)
CE-IVD or other non-FDA kitFull validation as an LDT
In-house assay transferred from your home labFull validation as an LDT
RUO componentsFull validation; see LDT vs IVD vs RUO

What you can reuse from home

  • Design rationale, risk analysis and known interferences.
  • Performance evaluation or ISO 15189 validation reports as a basis for acceptance criteria.
  • Characterised reference materials and panels.
  • Specimen stability data, if conditions match US transport.

Transfer plan

  1. Freeze the method: reagents, instrument, software version.
  2. Write a US validation plan the director approves before testing.
  3. Bridge with shared samples run at home and in the US.
  4. Complete analytical studies on US equipment.
  5. Set QC and PT or alternative assessment.
  6. Write the SOP and report format.
  7. Director sign-off; submit New York approval if serving New York.

Templates and detail: LDT validation plan and report template, LDT validation, LDT validation for cross-border testing.

Plan your US laboratory with us

Book a free consultation. Tell us your home country, test menu, target states and timing, and we will map the US licensing, director, validation and launch steps in order. Sound Lab Consultants is advisory: we work alongside your attorney and accountant.

Book a free consultation

Frequently asked questions

Can we use our home-country validation for CLIA?

Not on its own. The US lab must perform its own verification or validation on its system, though home data can guide the design.

Is a CE-IVD kit an LDT in the US?

If it is not FDA-authorized, a US lab using it must validate it as an LDT.

Which performance characteristics are required?

For LDTs: accuracy, precision, analytical sensitivity, analytical specificity including interfering substances, reportable range, reference intervals and any other characteristic required for performance.

Do we need New York approval for transferred assays?

Yes for LDTs used on New York specimens.

How do we handle PT for a novel assay?

Use alternative performance assessment at least twice a year where no PT exists.

Can SLC run our validation plan?

Yes. We design plans and review data with your US director.

Official sources

Sound Lab Consultants is an independent, advisory clinical laboratory consulting firm. This page is general information about US laboratory requirements, not legal, tax, immigration or customs advice. For entity, tax, investment-review or visa questions, work with a US attorney, a CPA and, for visas, an immigration attorney; always confirm current rules with the agency named. Sound Lab Consultants is not affiliated with or endorsed by CMS, FDA, CDC, OSHA, HHS, OIG, CAP, COLA, The Joint Commission, CLSI, ISO, ILAC, any national accreditation body or foreign regulator, any state agency, or any instrument or reagent manufacturer or distributor. Sound Lab Consultants, 25 Arizona Pl, Chandler, AZ 85225.