Pharmacogenomic (PGx) Testing
Pharmacogenomic (PGx) testing analyzes genes that affect how a person metabolizes or responds to medications. Variants in genes such as CYP2C19, CYP2D6 and CYP2C9 are translated into phenotypes (poor, intermediate, normal, rapid or ultrarapid metabolizer) that, with CPIC guidelines and FDA labeling, can guide drug choice and dosing.
- Specimen
- Buccal or saliva swabs collected per the validated device; blood if validated.
- CLIA complexity
- High complexity
- CLIA specialty
- Molecular genetics and genomics
- Common CPT codes
- 81225, 81226, 81227
How it works
- Specimen: Buccal swab, saliva or EDTA blood.
- Genotyping: Targeted genotyping (TaqMan OpenArray, MassARRAY) or sequencing detects defined variants; CYP2D6 also needs copy number (deletion/duplication) analysis.
- Translation: Variants are assigned star alleles, combined into a diplotype and translated to a phenotype.
- Report: Phenotype with gene-drug guidance from CPIC and FDA's Table of Pharmacogenetic Associations.
Common PGx genes
| Gene | Example drugs affected |
|---|---|
| CYP2C19 | Clopidogrel, many SSRIs, PPIs |
| CYP2D6 | Codeine, tramadol, tamoxifen, many antidepressants and antipsychotics |
| CYP2C9 and VKORC1 | Warfarin, NSAIDs, phenytoin |
| SLCO1B1 | Simvastatin and other statins |
| DPYD | Fluorouracil and capecitabine |
| TPMT and NUDT15 | Thiopurines |
| HLA-B*57:01, HLA-B*15:02 | Abacavir; carbamazepine |
Specimen collection
- Buccal or saliva swabs collected per the validated device; blood if validated.
Accuracy, results and interpretation
- PGx results do not change over time, so they can inform future prescribing.
- Medicare MolDX covers PGx testing when a drug with an actionable gene-drug interaction is being considered; broad panels without a clinical indication are a frequent audit and fraud focus.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Targeted genotyping | Thermo TaqMan OpenArray/QuantStudio, Agena MassARRAY | High (LDT) |
| Sequencing | Illumina NGS panels | High (LDT) |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 81225 | CYP2C19 gene analysis, common variants |
| 81226 | CYP2D6 gene analysis, common variants and duplication/deletion |
| 81227 | CYP2C9 gene analysis, common variants |
| 81418 | Drug metabolism panel of at least 6 genes including CYP2C19, CYP2D6 and CYP2D6 duplication/deletion |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Clinical PGx panels are high complexity LDTs: validate accuracy against reference materials (such as GeT-RM samples), CYP2D6 copy number calls, and the genotype-to-phenotype translation.
- New York requires State approval for PGx tests on New York patients.
- There is limited formal PT; use CAP PGx surveys or alternative assessment twice a year (42 CFR 493.1236(c)).
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the molecular genetics and genomics specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)). |
| Proficiency testing | Where no approved proficiency testing exists for a test, verify its accuracy at least twice a year, for example by split-sample comparison or an available external survey (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Molecular genetics and genomics lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Pharmacogenomic
Bringing Pharmacogenomic in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Is pharmacogenomic testing covered by insurance?
Coverage depends on the payer and indication. Medicare MolDX covers testing when a specific drug with an actionable gene-drug interaction is being considered.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.