Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultants › Lab test guides › Next-generation sequencing (NGS) test

Next-Generation Sequencing (NGS) Test

Reviewed November 28, 2026 by the Sound Lab Consultants laboratory team · Molecular genetics and genomics

Short answer

A next-generation sequencing (NGS) test reads millions of DNA or RNA fragments in parallel to find genetic variants across many genes at once. Clinical NGS is used for tumor profiling to guide targeted cancer therapy, hereditary cancer and other germline panels, exome and genome sequencing, and pathogen identification.

Specimen
FFPE tissue with adequate tumor content (pathologist-marked), plasma in cfDNA tubes, blood or saliva for germline.
CLIA complexity
High complexity
CLIA specialty
Molecular genetics and genomics
Common CPT codes
81445, 81450, 81455

How it works

  1. Library preparation: DNA or RNA is fragmented, target regions are captured or amplified, and adapters and barcodes are added.
  2. Sequencing: Sequencing-by-synthesis (Illumina) or semiconductor sequencing (Ion Torrent) generates reads.
  3. Bioinformatics: Reads are aligned to the reference genome; variants (SNVs, indels, copy number, fusions) are called and filtered.
  4. Interpretation: Variants are classified (AMP/ASCO/CAP tiers for tumors; ACMG/AMP for germline) and reported.

Types of clinical NGS tests

TestSpecimenUse
Tumor (somatic) panelFFPE tissueTargeted therapy, clinical trials
Liquid biopsyPlasma cell-free DNATumor profiling when tissue is limited
Hereditary (germline) panelBlood or salivaBRCA1/2, Lynch syndrome and other cancer risk genes
Exome/genomeBloodRare disease diagnosis
MetagenomicCSF, plasmaUnbiased pathogen detection

Specimen collection

Accuracy, results and interpretation

Methods, platforms and CLIA complexity

ApproachExamplesTypical CLIA category
Short-read sequencersIllumina MiSeq Dx, NextSeq, NovaSeqHigh
Semiconductor sequencingIon Torrent GenexusHigh

CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.

Billing codes

CodeDescription (summarized)
81445Solid organ neoplasm targeted sequencing, 5-50 genes
81450Hematolymphoid neoplasm, 5-50 genes
81455Solid organ or hematolymphoid neoplasm, 51 or more genes
PLA codesProprietary panels (for example FoundationOne CDx, 0037U)

CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.

Offering this test in your lab

CLIA requirements checklist

RequirementWhat CLIA requires
CLIA certificateA Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the molecular genetics and genomics specialty to your certificate before reporting results.
PersonnelHigh complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423).
Facility and workflowAmplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)).
Before patient testingVerify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253).
Quality controlControl procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)).
Proficiency testingWhere no approved proficiency testing exists for a test, verify its accuracy at least twice a year, for example by split-sample comparison or an available external survey (42 CFR 493.1236(c)).
CompetencyAssess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451).
RecordsKeep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105).

For specialty-level requirements and common survey findings, see Molecular genetics and genomics lab consulting and how to start a molecular PCR lab.

How Sound Lab Consultants helps labs offering Next-generation sequencing

BuildTest menu and complexity, CMS-116 and state licensure, space and workflow, instruments, SOPs, QC and PT enrollment. OverseeLaboratory director, technical consultant and technical supervisor coverage with documented oversight. ValidateMethod verification for FDA-cleared tests and full validation for modified tests and LDTs. RemediateMock inspections, plans of correction, PT failures and cease-testing responses.

Bringing Next-generation sequencing in-house?

Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.

Book a free consultationAll lab test guides

Or call (602) 874-1311 · info@soundlabconsult.com

Frequently asked questions

How long does an NGS test take?

Typically 1 to 3 weeks from specimen receipt, depending on the panel, batching and interpretation.

Related lab test guides

Pharmacogenomic (PGx) testPharmacogenomic (PGx) testing analyzes genes that affect how a person metabolizes or responds to medications.Laboratory developed test (LDT) validationValidating a laboratory developed test (LDT) means establishing its performance before patient testing: accuracy, precision, analytical sensitivity (l.Immunohistochemistry (IHC)Immunohistochemistry (IHC) uses antibodies that bind specific proteins in a thin tissue section, with a chromogen that makes the bound antibody visibl.

Sources

Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.