GI Pathogen Panel (Stool PCR)
A gastrointestinal (GI) pathogen panel is a multiplex PCR test that detects the nucleic acid of many bacteria, viruses and parasites that cause infectious diarrhea from one stool sample, usually in about an hour. Large panels cover more than 20 targets including Salmonella, Shigella, Campylobacter, Shiga toxin-producing E. coli, norovirus, rotavirus, Giardia and Cryptosporidium.
- Specimen
- Stool in Cary-Blair medium within the stability window.
- CLIA complexity
- Moderate to high, depending on the test system
- CLIA specialty
- Bacteriology (CLIA microbiology subspecialty)
- Common CPT codes
- 87505, 87506, 87507
How it works
- Stool in Cary-Blair: Stool is placed in Cary-Blair or another approved transport medium.
- Multiplex PCR: All targets are amplified and detected together in a pouch or cartridge.
- Report and reflex: Positives for reportable bacteria (Salmonella, Shigella, STEC) may need culture for public health and susceptibility testing.
Typical GI panel targets
- Bacteria: Campylobacter, C. difficile toxin A/B, Plesiomonas, Salmonella, Vibrio (including V. cholerae), Yersinia, enteroaggregative, enteropathogenic, enterotoxigenic and Shiga toxin-producing E. coli (including O157), Shigella/EIEC
- Parasites: Cryptosporidium, Cyclospora cayetanensis, Entamoeba histolytica, Giardia
- Viruses: adenovirus F40/41, astrovirus, norovirus GI/GII, rotavirus A, sapovirus
Specimen collection
- Stool in Cary-Blair medium within the stability window.
- Testing patients with diarrhea lasting less than about 7 days in the community is often low-yield; payers apply criteria.
Accuracy, results and interpretation
- Detects nucleic acid from dead organisms and carriers; correlate with symptoms.
- Smaller targeted panels (3 to 5 targets) are covered more readily by some payers.
Methods, platforms and CLIA complexity
| Approach | Examples | Typical CLIA category |
|---|---|---|
| Large syndromic panels | BioFire GI Panel, QIAstat-Dx Gastrointestinal Panel 2, Verigene EP | Moderate |
| Targeted bacterial panels | BD MAX Enteric Bacterial Panel, Xpert | Moderate to high |
CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.
Billing codes
| Code | Description (summarized) |
|---|---|
| 87505 | GI pathogen, multiplex amplified probe, 3-5 targets |
| 87506 | Same, 6-11 targets |
| 87507 | Same, 12-25 targets |
CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.
Offering this test in your lab
- Coordinate with your state public health lab on culture-independent results: many states require isolates or specimens for Salmonella, Shigella and STEC.
- Medicare MolDX (LCD L39044) sets coverage criteria for syndromic GI panels.
CLIA requirements checklist
| Requirement | What CLIA requires |
|---|---|
| CLIA certificate | A Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results. |
| Personnel | High complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423). |
| Facility and workflow | Amplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)). |
| Before patient testing | Verify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253). |
| Quality control | Control procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261. |
| Proficiency testing | Enroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)). |
| Competency | Assess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451). |
| Records | Keep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105). |
For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.
How Sound Lab Consultants helps labs offering Gastrointestinal
Bringing Gastrointestinal in-house?
Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.
Book a free consultationAll lab test guidesOr call (602) 874-1311 · info@soundlabconsult.com
Frequently asked questions
Does a GI panel replace a stool culture?
For detection, largely yes. Culture is still needed for susceptibility testing and for public health isolates of reportable bacteria.
Does a GI panel detect C. diff?
Many large panels include C. difficile toxin genes, but C. diff testing should follow the lab's C. diff algorithm and stool criteria.
Related lab test guides
Sources
Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.