Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultants › Lab test guides › C. difficile test

C. diff Test

Reviewed November 28, 2026 by the Sound Lab Consultants laboratory team · Bacteriology (CLIA microbiology subspecialty)

Short answer

A C. diff test looks for Clostridioides difficile infection in a loose stool sample. Labs use a NAAT (PCR) for the toxin genes, an immunoassay (EIA) for free toxins A and B, a glutamate dehydrogenase (GDH) antigen test, or a multistep algorithm that combines them, because PCR alone cannot tell colonization from active toxin-producing infection.

Specimen
Unformed stool in a clean container, tested promptly or refrigerated per the assay.
CLIA complexity
Moderate to high, depending on the test system
CLIA specialty
Bacteriology (CLIA microbiology subspecialty)
Common CPT codes
87493, 87324, 87449

How it works

  1. Specimen check: Only unformed (liquid or soft) stool from patients with at least 3 unexplained loose stools in 24 hours should be tested; formed stool is rejected.
  2. Screening: GDH antigen and/or toxin gene PCR.
  3. Confirmation: A toxin EIA distinguishes active infection from colonization in algorithm-based testing.

Common C. diff testing algorithms

ApproachSteps
NAAT aloneToxin gene PCR; use only with strict stool acceptance criteria
GDH + toxin, arbitrate by NAATGDH and toxin EIA together; discordant results go to PCR
NAAT + toxinPCR first; positives reflex to toxin EIA

Specimen collection

Accuracy, results and interpretation

Methods, platforms and CLIA complexity

ApproachExamplesTypical CLIA category
Toxin gene PCRXpert C. difficile, BD MAX Cdiff, cobas Cdiff, GI syndromic panelsModerate to high
GDH + toxin EIAC. DIFF QUIK CHEK COMPLETE and similar membrane EIAsModerate (check the exact kit)

CLIA complexity is assigned to each specific test system (instrument, reagent and specimen type), not to a method in general. Confirm yours in the FDA CLIA database or our weekly list of new FDA CLIA categorizations.

Billing codes

CodeDescription (summarized)
87493C. difficile toxin gene(s), amplified probe
87324C. difficile toxin(s) antigen, immunoassay
87449Antigen detection, immunoassay, not otherwise specified (GDH, payer-specific)

CPT is a registered trademark of the American Medical Association. Descriptions are summarized; check the current CPT code set, your MAC's coverage articles and each payer's policy before billing.

Offering this test in your lab

CLIA requirements checklist

RequirementWhat CLIA requires
CLIA certificateA Certificate of Waiver covers only test systems FDA has categorized as waived (42 CFR 493.15). Moderate and high complexity testing needs a Certificate of Compliance or a Certificate of Accreditation (CAP, COLA, The Joint Commission and others) after a Registration certificate (42 CFR 493.43). Add the bacteriology specialty to your certificate before reporting results.
PersonnelHigh complexity: laboratory director (42 CFR 493.1443), technical supervisor (42 CFR 493.1449), general supervisor (42 CFR 493.1461) and qualified testing personnel (42 CFR 493.1489). Moderate complexity: director (42 CFR 493.1405), technical consultant (42 CFR 493.1411) and testing personnel (42 CFR 493.1423).
Facility and workflowAmplification not contained in a closed system needs a unidirectional workflow with separate areas for specimen preparation, amplification and detection, and reagent preparation (42 CFR 493.1101(a)(3)).
Before patient testingVerify accuracy, precision, reportable range and reference intervals for an unmodified FDA-cleared test; fully validate a modified test or LDT (42 CFR 493.1253).
Quality controlControl procedures for every run under 42 CFR 493.1256, including two controls for each molecular amplification procedure and an inhibition control where inhibition causes false negatives (42 CFR 493.1256(d)(3)(v)), plus the specialty rules in 42 CFR 493.1261.
Proficiency testingEnroll in an approved program for regulated analytes (42 CFR 493.911). For analytes without required PT, verify accuracy at least twice a year (42 CFR 493.1236(c)).
CompetencyAssess each person's competency semiannually in the first year and annually after that, using the six required methods (42 CFR 493.1235 with the director and supervisor duties in 42 CFR 493.1451).
RecordsKeep QC, PT, maintenance and test records for at least 2 years, and longer for some specialties and states (42 CFR 493.1105).

For specialty-level requirements and common survey findings, see Bacteriology lab consulting and how to start a molecular PCR lab.

How Sound Lab Consultants helps labs offering C. difficile test

BuildTest menu and complexity, CMS-116 and state licensure, space and workflow, instruments, SOPs, QC and PT enrollment. OverseeLaboratory director, technical consultant and technical supervisor coverage with documented oversight. ValidateMethod verification for FDA-cleared tests and full validation for modified tests and LDTs. RemediateMock inspections, plans of correction, PT failures and cease-testing responses.

Bringing C. difficile test in-house?

Our laboratory consultants scope the test menu, pick the platform, write the validation plan and procedures, and provide the director and technical oversight CLIA requires, for clinics, urgent cares, hospitals and independent labs in every state.

Book a free consultationAll lab test guides

Or call (602) 874-1311 · info@soundlabconsult.com

Frequently asked questions

Why was my C. diff PCR positive but toxin negative?

The patient carries a toxin-producing strain but free toxin was not detected, which can mean colonization rather than infection. Clinical judgment decides treatment.

Related lab test guides

Gastrointestinal (GI) pathogen panelA gastrointestinal (GI) pathogen panel is a multiplex PCR test that detects the nucleic acid of many bacteria, viruses and parasites that cause infect.Syndromic PCR panelsSyndromic PCR panels are multiplex molecular tests that check one specimen for all the common pathogens that cause a clinical syndrome, such as respir.Real-time PCR (qPCR) testA real-time PCR (qPCR) test copies a target DNA sequence through repeated heating and cooling cycles and measures the fluorescent signal after every c.

Sources

Educational content for laboratories and clinicians, reviewed November 28, 2026. Not medical, legal or billing advice. Product names are trademarks of their owners and are listed as examples only; Sound Lab Consultants is independent and not affiliated with CMS, CDC, FDA or any manufacturer.